MAINTENANCE
31
7. Drain the carburetor according to the instructions on page 26.
8. Store the emptied gasoline in a suitable place. DO NOT store flammable materials near the gasoline.
Do not store fuel for more than 3 months.
TESTING THE GFCI OUTLET
Test the GFCI outlet monthly. The GFCI outlet has two buttons between the outlets
(refer to Fig. 22):
• RESET (upper)
• TEST (lower)
To test:
1. Start the generator according to the instructions in this manual. Wait a few
minutes for the generator to stabilize its speed and voltage output.
2. Press the RESET button on the GFCI outlet (Fig. 22).
3. Connect a device to the outlet and turn it ON.
4. With the device ON, press the TEST button on the GFCI outlet. The power to the
device should be cut off instantly, and the device should turn OFF.
CAUTION: Store the emptied gasoline in a suitable place. Never store fuel for more than 2 months.
CAUTION: If the device does not instantly turn OFF, you may have a faulty GFCI outlet. Call customer service
(800) 232-1195 M-F 8-5 CST or email techsupport@wenproducts.com for assistance in replacing the outlet.
5. Disconnect the device from the outlet and press the RESET button again. Shut down the generator normally.
Fig. 22