Lit. No. 49513, Rev. 00 89 August 15, 2011
HYDRAULIC SYSTEM
Fluid Level
NOTE: On MVP PLUS™ and WIDE-OUT™
blades, add uid only when all rams are
retracted.
NOTE: Remove ll plug slowly to relieve any
pressure in reservoir.
MAINTENANCE
1. With the UltraMount
®
2 system attached to the
vehicle, activate the control.
2. For straight blades, any angle will do, but for
MVP PLUS and WIDE-OUT blades, move
blade wings to fully retracted (vee) position.
3. Activate the control FLOAT function and
manually collapse the lift ram all the way.
Fill
Plug
Drain
Plug
Straight Blades MVP PLUS Blades
Fill
Plug
Drain
Cap
CAUTION
Do not mix different kinds of hydraulic
uid. Some uids are not compatible and
may cause performance problems and
product damage.