detection, system waits for consumer intervention to open the Lid
distribute the cloths and then to press start key
detection will be a permanent Ub error &
Ensure the laundry in a balanced distribution.
Check whether the water in the system is completely draining or not.
Ensure that there are 24 PIP in the system drive ( Run Line Test Routine
here is any PIP breakage there it will be detected as “PIP”)
Ensure that the capacitor doesn’t have degraded.
Check whether the system is running smooth.
When the input voltage at consumer end falls below 170V & above 270V then “PE”
Ensure that the Input voltage is above 170V & below 270V
RID#2.8. LID OPEN ERROR
1)
If there is no feedback from Lid Switch, then “Lid Op
Ensure the Lid is firmly closed
Check for Lid switch operation & its connections
Keys are shorted, then ‘tSC’ error will be popped & this error is applicable only in
Test Routines.
2)
Need to check:
a)
Ensure that there is a required interval given while invoking Test Routines.
Keys shorted in User Interface
detection, system waits for consumer intervention to open the Lid
distribute the cloths and then to press start key
detection will be a permanent Ub error &
the same cannot be rectified by
Ensure the laundry in a balanced distribution.
Check whether the water in the system is completely draining or not.
Ensure that there are 24 PIP in the system drive ( Run Line Test Routine
here is any PIP breakage there it will be detected as “PIP”)
Ensure that the capacitor doesn’t have degraded.
Check whether the system is running smooth.
When the input voltage at consumer end falls below 170V & above 270V then “PE”
Ensure that the Input voltage is above 170V & below 270V
If there is no feedback from Lid Switch, then “Lid Op
n” error will be popped till
Ensure the Lid is firmly closed
Check for Lid switch operation & its connections
Keys are shorted, then ‘tSC’ error will be popped & this error is applicable only in
Ensure that there is a required interval given while invoking Test Routines.
Keys shorted in User Interface
detection, system waits for consumer intervention to open the Lid
the same cannot be rectified by
Check whether the water in the system is completely draining or not.
Ensure that there are 24 PIP in the system drive ( Run Line Test Routine
here is any PIP breakage there it will be detected as “PIP”)
When the input voltage at consumer end falls below 170V & above 270V then “PE”
Ensure that the Input voltage is above 170V & below 270V
n” error will be popped till
Keys are shorted, then ‘tSC’ error will be popped & this error is applicable only in
Ensure that there is a required interval given while invoking Test Routines.