EasyManua.ls Logo

Whynter ARC-148MS User Manual

Whynter ARC-148MS
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
WHYNTER 14,000 BTU PORTABLE AIR CONDITIONER
Congratulations on your new Whynter product. To ensure proper operation, please read this Instruction Manual carefully before
using this product. Keep this manual in a safe place for future reference.
Model # : ARC-148MS
INSTRUCTION MANUAL

Questions and Answers:

Whynter ARC-148MS Specifications

General IconGeneral
Typeportable
Operating Area Size500 square feet
Cooling Settings1
Seasonally Adjusted Cooling Capacity8400 british thermal units
Heaterno
Fan Speeds3
Fan Airflow Rate292 cubic feet per minute
Hosesingle
Remote Controlyes
Timeryes
Sleeping Modeyes
Energy Efficiency8.86

Summary

General Safety Precautions

Safety Precautions

Important safety instructions before operation and installation.

Cautionary Safety Advice

Appliance not for use by persons with reduced physical, sensory, or mental capabilities.

Warning Safety Advice

Do not use hazardous chemicals, operate near ignition sources, or pierce/burn.

Safety Compliance and Regulations

Adherence to national gas regulations and handling of flammable refrigerants.

Fire and Flammable Material Risks

Explains symbols related to flammable refrigerants and fire risks.

Servicing Information and Precautions

Details on checks, work procedures, general work area, and refrigerant presence.

Refrigeration System Checks

Checks for correct specifications, ventilation, and refrigerant presence.

Electrical Device Checks

Initial safety checks for electrical components, capacitors, and earth bonding.

Repair of Intrinsically Safe Components

Guidelines for working on intrinsically safe components with flammable atmospheres.

Flammable Refrigerant Detection

Methods for detecting refrigerant leaks using electronic detectors.

Refrigerant Charging Procedures

Requirements for charging the refrigeration system with refrigerant.

Unit Decommissioning

Procedures for safely removing refrigerant and decommissioning the unit.

Installation Instructions

Installation Preparation and Design Notes

General notes on illustrations, unit control, and specification changes.

Operating Conditions and Hose Installation

Optimal temperature ranges, and instructions for exhaust hose installation.

Choosing the Right Location

Requirements for optimal placement of the unit.

Energy Rating Information

Recommendations for efficient operation and hose usage.

Air Conditioner Selection Guide and SACC

Guidance on selecting units and definition of Seasonally Adjusted Cooling Capacity.

Technical Data

Specifications of the ARC-148MS model.

Installation Tools Required

List of tools required for installation.

Filter Management and Water Drainage

Information on installing filters and managing water drainage.

Manual and Continuous Drainage

Steps for draining water manually or via continuous drainage.

Unit Placement and Exhaust Hose Setup

Guidelines for unit placement and exhaust hose setup.

Window Kit Installation Guide

Detailed steps for installing the window kit in different window types.

Hose Installation to Window Kit

Connecting the exhaust hose to the installed window kit.

Operating Instructions

Control Panel and Display Functions

Explanation of control panel buttons, display, and error codes.

Operation Modes and Timer Function

Initial setup, modes (Cool, Dry, Auto, Fan), and timer functions.

Advanced Operating Features

Covers Sleep, Auto Restart, Airflow, noise, compressor lockout, and shortcut.

Remote Control Operation and Features

Using the remote control, including transmission, buttons, indicators, and batteries.

Maintenance

Air Filter Maintenance

Steps for removing, cleaning, and reinstalling the unit's air filters.

Exterior Cleaning

Instructions for cleaning the exterior of the unit with a soft damp cloth.

Seasonal Storage

Procedures for safely storing the air conditioner when not in use.

Maintenance Safety Warnings

Important safety notes regarding operation without filters and maintenance.

Troubleshooting Tips

Troubleshooting: Unit Not Turning On

Possible causes and solutions for the unit failing to power on.

Troubleshooting: Unit Runs Without Cooling

Causes and solutions for the unit running without cooling, including time delay.

Troubleshooting: Weak Cooling or Airflow

Reasons for weak cooling or airflow and their solutions.

Troubleshooting: Insufficient Cooling

Causes and solutions for insufficient cooling over time.

Troubleshooting: Noise and Water Leaks

Potential causes for excessive noise and water leakage, and their solutions.

Troubleshooting: Fan Speed Issues

Possible reasons why fan speed is not adjustable.

Limited Warranty and Compressor Warranty

Warranty Limitations and Exclusions

List of conditions and damages not covered by the warranty.

Warranty Disclaimers and Legal Notices

Legal disclaimers regarding implied warranties and damages.

Related product manuals