WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER WITH HEATER
co
Instruction Manual
MODEL# : ARC-14SH
Congratulations on your new WHYNTER product. To ensure proper operation, please read this Instruction
Manual carefully before using this product. Keep this manual in a safe place for future reference.

Other manuals for Whynter ARC-14SH

Questions and Answers

  • N
    Nicole OlsonAug 21, 2025
    Why is my Whynter ARC-14SH Air Conditioner running but not cooling?
    • D
      david94Aug 21, 2025
      If your Whynter Air Conditioner turns on, but the compressor doesn't (the fan runs, but it's not cooling), it could be due to several reasons. The room temperature might be outside the unit's operational range of 64°F to 95°F. Ensure the Cooling mode is selected by pressing the MODE button until the COOL light appears. Allow the compressor 3 minutes to start after selecting Cooling mode. Also, the set temperature might be too high; try setting it lower, ideally at least 5°F below the ambient temperature. Lastly, if the internal water reservoir is full, drain it manually or run the fan-only mode to exhaust the water.
  • K
    Karen JohnsonAug 23, 2025
    How to fix a Whynter ARC-14SH that does not turn on?
    • A
      Ashley FosterAug 23, 2025
      There are several reasons why your Whynter Air Conditioner might not be turning on. First, check for a power outage or tripped breaker and restore power. If the power supply voltage is too low, move the unit to a circuit with the correct voltage. Also, the L.C.D.I. power plug might be tripped; in that case, press the Reset button on the plug. If the internal water reservoir is full, drain the water. For a damaged power cord, contact Whynter Service Department.
  • S
    Steven FordAug 26, 2025
    Why is my Whynter Air Conditioner's fan running but not cooling?
    • C
      Christine GomezAug 26, 2025
      If your Whynter Air Conditioner turns on but isn't cooling, ensure that the Cooling mode is activated by pressing the MODE button until the COOL light appears. Allow the compressor 3 minutes to start after selecting Cooling mode. Also, make sure the set temperature isn't too high; it's best to set it at least 5°F lower than the room temperature. Check if the internal water reservoir is full and drain it.
  • E
    esnyderAug 28, 2025
    What to do if my Whynter ARC-14SH Air Conditioner is leaking water?
    • W
      William JenkinsAug 28, 2025
      If your Whynter Air Conditioner is leaking water, ensure the unit is leveled. If not, adjust it to be level. Also, drain the water from the drain plug at the back of the air conditioner.
  • H
    hannahpayneAug 30, 2025
    Why is the air from my Whynter ARC-14SH Air Conditioner not cold enough?
    • H
      Hailey MckayAug 30, 2025
      If the air from your Whynter Air Conditioner isn't cold or the airflow is weak, start by cleaning the air filters. Ensure that the air intake and exhaust aren't blocked, keeping at least 20" of clearance from the intake and shortening the exhaust hose. Check that the unit is in cooling mode, not DRY or FAN mode, and that the fan speed is set appropriately.
  • K
    Kenneth ColonSep 1, 2025
    What to do if Whynter ARC-14SH isn't cooling room enough?
    • J
      Jesus SchwartzSep 1, 2025
      If your Whynter Air Conditioner isn't cooling the room effectively, close any open windows and doors. If there are many people in the room, or if the room is a kitchen with heat-producing appliances, or if there is direct sunshine, consider additional cooling solutions. The same applies if the room is too large.
  • A
    anthony11Sep 3, 2025
    Why does my Whynter Air Conditioner need to be drained so often?
    • B
      Brenda ParkerSep 3, 2025
      If your Whynter Air Conditioner requires frequent draining, it might be due to high humidity. Try removing the intake hose if the outside humidity is high or if it's raining. For possible loose connection contact Whynter Service Department.
  • A
    aaronkerrSep 5, 2025
    What to do if my Whynter ARC-14SH does not turn on?
    • C
      Christopher GuerreroSep 5, 2025
      If your Whynter Air Conditioner doesn't turn on, several factors could be at play. First, there might be a power failure or outage, or the circuit breaker may have been tripped. Restore power and reset the breaker. Note that too many appliances on one circuit can cause issues, so try moving some to another circuit. Also, check if the power cord is damaged, and if so, call for authorized service. Press the Reset button on the L.C.D.I. power plug. Lastly, the internal water reservoir might be full, so drain the water from the air conditioner.
  • A
    Amy ShawSep 7, 2025
    Why Whynter ARC-14SH Air Conditioner unit has worked for a long time, but the room is not cold enough?
    • W
      Wesley CollinsSep 7, 2025
      If your Whynter Air Conditioner has been running for a while, but the room isn't cold enough, make sure all windows and doors are closed. You might need additional cooling or another air conditioner. Also, close curtains or blinds to minimize direct sunlight. You may need additional cooling or another air conditioner.
  • J
    Julie JonesSep 9, 2025
    Why is my Whynter ARC-14SH so noisy?
    • J
      Jonathan JohnsonSep 9, 2025
      If your Whynter Air Conditioner is very noisy, make sure it's on a hard, level, and stable surface. If the surface is uneven, move the unit to a location with a level and hard floor. Also, ensure the wall outlet supports the air conditioner's power consumption and avoid using an extension cord.

Summary

Safety Precautions

Operating Your Air Conditioner

Control Panel Overview

Explains the functions of buttons and displays on the unit's control panel.

Installation Instructions

Location and Clearance Requirements

Details where to place the unit and necessary space for ventilation.

Exhaust Hose Installation

Guides on how to connect and position the exhaust hose for hot air expulsion.

Window Kit Installation

Instructions for installing the window slider kit for exhaust hose setup.

Air Filters Installation

Operation Instructions

Cooling Mode Operation

Details how to use the cooling function, temperature settings, and fan speeds.

Dehumidifying Mode Operation

Explains dehumidification mode, compressor behavior, and hose venting.

Water Drainage

Remote Control

Care and Maintenance

Troubleshooting

Whynter ARC-14SH Specifications

General IconGeneral
Typeportable
Operating Area Size500 square feet
Cooling Settings3
Seasonally Adjusted Cooling Capacity8301.6 british thermal units
Heateryes
Fan Speeds3
Fan Airflow Rate212 cubic feet per minute
Hosedual
Remote Controlyes
Timeryes
Sleeping Modeno