Congratulations on your new Whynter product. To ensure proper operation, please read this Instruction Manual carefully before
using this product. Keep this manual in a safe place for future reference.
WHYNTER 13,500 BTU PORTABLE
AIR
CONDITIONER
WITH HEATER
Model
#
:
ARC-148MHP
INSTRUCTION MANUAL

Questions and Answers

  • S
    Sharon PriceAug 18, 2025
    How to fix Whynter ARC-148MHP that does not turn on?
    • L
      Lucas McdonaldAug 18, 2025
      If your Whynter Air Conditioner doesn't turn on, there might be several reasons. First, check for a power outage and restore the power supply if necessary. Then, verify that the automatic switch, line fuse, or breaker hasn't tripped; if it has, flip the switch, change the fuse, or turn the breaker back on. Note that too many appliances on one circuit could cause this, so try moving some to another circuit. Ensure the power supply voltage is correct, and if the power cord is damaged, call for service. Also, check the L.C.D.I. power plug and press the Reset button if it's tripped. Finally, drain any excess water from the internal reservoir. For possible loose internal connections, contact Whynter for service.
  • K
    Kelly JohnsonAug 20, 2025
    Why is my Whynter ARC-148MHP Air Conditioner running but not cooling?
    • J
      Joseph DavisAug 20, 2025
      If your Whynter Air Conditioner turns on, but the compressor isn't running, and it's not cooling, here's what you can check: First, ensure the room temperature is within the unit's operational range of 63°F to 90°F. Make sure the Cooling mode is activated by pressing the MODE button until the COOL light appears on the display. Remember that the compressor may take up to 3 minutes to start after selecting Cooling mode. Also, verify that the set temperature isn't too high; it's best to set it at least 5°F lower than the ambient temperature. Lastly, check if the internal water reservoir is full and drain it manually or by running the fan-only mode. For possible loose internal connections, contact Whynter for service.
  • J
    Joseph OsborneAug 23, 2025
    How to fix a Whynter ARC-148MHP that does not turn on?
    • S
      Shannon WhiteAug 23, 2025
      If your Whynter Air Conditioner doesn't turn on, here are a few things to check: * First, ensure there isn't a power outage. * Check the breaker or fuse and reset or replace if necessary. Also, too many appliances on one circuit can cause issues, so try moving some to another circuit. * Low voltage can be a problem, so try another circuit. * If the LCDI power plug is tripped, press the reset button on it. * Also, if 'P1' is displayed, it means the internal water reservoir is full and needs to be drained. * If none of these solutions work, there might be a loose internal connection, and you should contact Whynter for service.
  • R
    Roger BarberAug 26, 2025
    What to do if Whynter ARC-148MHP turns on but is not cooling?
    • R
      Rebekah WolfAug 26, 2025
      If your Whynter Air Conditioner turns on, but isn't cooling, consider these potential issues: * Ensure the room temperature is between 63°F and 90°F, as the unit is designed to work within this range. * Make sure the Cooling mode is selected by pressing the MODE button until the COOL light appears. * The compressor might be on a time delay; give it 3 minutes to start after selecting Cooling mode. * If the set temperature is too high, lower it, ideally to at least 5°F below the ambient temperature. * If 'P1' is on the display, drain the water reservoir or run the fan-only mode to exhaust the water. * If none of these steps work, there could be a loose internal connection, and you should contact Whynter for service.
  • G
    gcolemanAug 28, 2025
    What to do if Whynter ARC-148MHP Air Conditioner is not cooling room enough?
    • J
      James RiosAug 28, 2025
      If your Whynter Air Conditioner has been running for a while, but the room isn't getting cold enough, consider these factors: Make sure all windows and doors are closed. If there are too many people in the room, or if the room is a kitchen or contains many heat-producing appliances or a server, you might need additional cooling or another air conditioner. Also, try to minimize direct sunlight by closing curtains or blinds. Finally, if the room is too large for the unit, you may need additional cooling or another air conditioner.
  • S
    Shawn AlexanderAug 30, 2025
    Why is the air from my Whynter ARC-148MHP not cold?
    • E
      Edward CantrellAug 31, 2025
      If the air coming out of your Whynter Air Conditioner isn't very cold or the airflow is weak, try these solutions: Begin by cleaning the air filters, as they may be dirty or obstructed. Ensure that the air intake and exhaust are not blocked, providing at least 20" of clearance from the air intake and keeping the exhaust hose as short as possible. Check that the unit is set to cooling mode, not DRY or FAN mode. Finally, increase the fan speed if it's set too low.
  • J
    Joel RosarioSep 2, 2025
    Why is my Whynter ARC-148MHP not cooling enough?
    • H
      hurleyericSep 2, 2025
      If your Whynter Air Conditioner isn't cooling the room sufficiently, consider the following: * Ensure all windows and doors are closed. * If there are many people in the room, or a server is running, you might need additional cooling. * Minimize direct sunlight by closing curtains or blinds. * If the room is too large for the unit, consider an additional air conditioner.
  • M
    markpittsSep 4, 2025
    How to reduce noise from Whynter ARC-148MHP Air Conditioner?
    • H
      hardinlynnSep 4, 2025
      If your Whynter Air Conditioner is very noisy, make sure it is on a hard, level, and stable surface. If the surface underneath the unit is uneven, move it to a location with a level and hard floor. Also, ensure that the wall outlet can support the air conditioner's power consumption and avoid using an extension cord.
  • N
    Nicholas RosarioSep 7, 2025
    Why is my Whynter ARC-148MHP leaking water?
    • D
      David ClarkeSep 7, 2025
      If your Whynter Air Conditioner is leaking water, ensure that the unit is leveled. Also, check if the water tank is full and drain it using the drain plug at the back of the unit.
  • R
    Roger ParrishSep 9, 2025
    Why can't I change the fan speed on my Whynter Air Conditioner?
    • S
      Sarah ParrishSep 9, 2025
      If you cannot change the fan speed on your Whynter Air Conditioner, note that the fan speed difference is not very noticeable when the compressor is on. Try setting the unit to Fan only mode; you should be able to hear the difference between high and low fan speed settings then.

Summary

Safety Precautions

General Safety Warnings

Crucial instructions to prevent hazards like electric shock, fire, and injury.

Refrigerant and Flammable Material Safety

Guidelines for refrigerant handling, ventilation, and avoiding ignition sources.

Operating Instructions

Maintenance

Air Filter Care and Storage

Air filter cleaning, replacement, and end-of-season storage procedures.

Troubleshooting Tips

Unit Power and Cooling Issues

Solutions for the unit not turning on or the compressor not cooling.

Airflow and Performance Problems

Reasons and fixes for weak airflow or insufficient cooling.

Common Operational Issues

Troubleshooting for inadequate cooling, unit noise, and water leaks.

Whynter ARC-148MHP Specifications

General IconGeneral
Model NumberARC-148MHP
TypePortable Air Conditioner
Heating Capacity13, 000 BTU
Coverage Area500 sq. ft.
Power Supply115V/60Hz
RefrigerantR-410A
Weight80 lbs
Exhaust Hose Diameter5 inches
Fan Speeds3
Thermostat Range61°F - 89°F
Cooling Capacity14, 000 BTU
Noise Level56 dB
Power Consumption Cooling1, 300 W
Filter TypeWashable Pre-Filter
Exhaust Hose Length60 inches
FeaturesRemote control
Dehumidifying Capacity101 pints per day