22 WIKA operating instructions pressure transmitter, model S-10
1604457.16 09/2017 EN/DE/FR/ES
Specications
Operating conditions
Ingress protection The stated ingress protection only applies when plugged in using mating connectors that have
the appropriate ingress protection.
Angular connector DIN 175301-803 A IP65
Angular connector DIN 175301-803 with ½ NPT IP65
Circular connector M12 x 1 (4-pin) IP67
Bayonet connector (6-pin) IP67
½ NPT conduit male, with cable outlet IP67
Cable outlet (standard) IP67
Cable outlet (not adjustable) IP68
Cable outlet (adjustable) IP68
Shock resistance 1,000 g (IEC 60068-2-27, mechanical)
Vibration resistance 20 g (per IEC 60068-2-6)
Permissible temperature ranges Medium: -30 ... +100 °C (option: -40 ... +125 °C)
Ambient: -20 ... +80 °C
Storage: -40 ... +100 °C
Pollution degree max. 3
Humidity ≤ 80 % r. h. (non-condensing)