en Installation and electrical connection
16 WILO SE 2019-04
5.3 Storage
NOTICE
Improper storage can lead to damage to the equipment.
Damage caused by improper storage is not covered by the guarantee or warranty.
Requirements at the storage location:
dry
clean
well-ventilated
free from vibrations
free from humidity
free from rapid or extreme changes in temperature
Store the product somewhere safe against mechanical damage.
Protect the bearings and couplings from sand, gravel and other foreign objects.
Lubricate the unit to prevent rust and bearing seizing.
Manually rotate the drive shaft several times once a week.
Storage for more than three months
Additional precautionary measures:
All rotating parts must be coated with a suitable protective medium to protect them
from rust.
If the pump is to be stored for more than a year, consult the manufacturer.
6 Installation and electrical con-
nection
6.1 Personnel qualifications
Electrical work: A qualified electrician must carry out the electrical work.
6.2 Operator responsibilities
Observe locally applicable accident prevention and safety regulations of professional
and trade associations.
Observe all regulations for working with heavy loads and under suspended loads.
Provide protective equipment and ensure that the protective equipment is worn by
personnel.
Avoid pressure surges!
Pressure surges can occur in long pressure pipes. These pressure surges can lead to the
destruction of the pump!
Structural components and foundations must be of sufficient stability in order to allow
the device to be fixed in a secure and functional manner. The operator is responsible for
the provision and suitability of the building/foundation!
Check that the available consulting documents (installation plans, design of the operat-
ing space, inflow conditions) are complete and correct.
6.3 Preparing the installation
WARNING
Risk of personal injury and property damage due to improper handling!
Never set up the pump unit on unfortified surfaces or surfaces that cannot bear
loads.
The pump should only be installed after completion of all welding and soldering
work.
Flush the pipe system if required. Dirt can cause the pump to fail.
The pumps (in the standard version) must be protected from the weather and installed
in a frost/dust-free, well-ventilated environment that is not potentially explosive.
Mount the pump in a readily accessible place. This makes it easier to complete inspec-
tions, maintenance (e.g. mechanical seal change) or replacement in the future.
A travelling crane or a device for attaching hoisting gear should be installed above the
set-up site of large pumps.