EasyManuals Logo
Home>Wilo>Water Pump>Wilo-Para /SC Series

Wilo Wilo-Para /SC Series User Manual

Wilo Wilo-Para /SC Series
29 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
Installation and operating instructions Wilo-Para 41
en
Align the upper shut-off device laterally.
When installing in the feed of open systems, the
safety supply must branch off upstream of the
pump (EN 12828).
Complete all welding and brazing work.
Flush the pipe system.
Do not use the pump to flush the pipe system.
Installing the pump Observe the following points when installing the pump:
Note the direction arrow on the pump housing (1).
Install glandless motor (2) horizontally, without
mechanical tension.
Place gaskets in the screwed connections.
Screw on threaded pipe unions.
Use an open-end wrench to secure the pump against
twisting and screw tightly to piping.
Re-mount the thermal insulation shell if required.
CAUTION!
Leaking water may damage the control module.
Align the upper shut-off device so that leaking
water cannot drip onto the control module (5).
If the control module is sprayed with liquid, the sur-
face must be dried off.
1
2
3
CAUTION!
Insufficient heat dissipation and condensation water
may damage the control module and the glandless
motor.
Do not thermally insulate the glandless motor (2).
Ensure all condensate drain openings (3) are kept
free.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wilo Wilo-Para /SC Series and is the answer not in the manual?

Wilo Wilo-Para /SC Series Specifications

General IconGeneral
BrandWilo
ModelWilo-Para /SC Series
CategoryWater Pump
LanguageEnglish

Related product manuals