Installation and operating instructions Wilo-Rexa MINI3 11
ƒ Ingestion: In general, no treatment is neces-
sary. If larger amounts have been swallowed,
consult a doctor.
2 Product description and function
2.1 Description
Submersible pump for stationary and portable wet well in-
stallation in intermittent operation.
1
2
3
4
5
6
Fig.1: Overview
1 Handle
2 Motor housing
3 Discharge connection
4 Pump housing
5 Float switch
6 Connection cable
Rexa MINI3-V...-P
Sewage pump with vortex impeller and vertical threaded
connection. Hydraulics housing made of grey cast iron, im-
peller made of plastic. Surface-cooled 1~ motor with integ-
rated operating capacitor and self-switching thermal motor
monitoring. Stainless steel motor housing. Oil-filled sealing
chamber with double sealing: a rotary shaft seal is installed
on the motor side, a mechanical seal on the pump side. De-
tachable connection cable with fitted shockproof plug.
Rexa MINI3-V...-A
Sewage pump with vortex impeller and vertical threaded
connection. Hydraulics housing made of grey cast iron, im-
peller made of plastic. Surface-cooled 1~ motor with integ-
rated operating capacitor and self-switching thermal motor
monitoring. Stainless steel motor housing. Oil-filled sealing
chamber with double sealing: a rotary shaft seal is installed
on the motor side, a mechanical seal on the pump side. De-
tachable connection cable with float switch and fitted
shockproof plug.