Installation and operating instructions Wilo-Rexa MINI3 13
M
Mains connection version:
ƒ M = single-phase current (1~)
ƒ T = three-phase current (3~)
06
Value/10 = rated power P
2
in kW
5
Mains frequency:
ƒ 5 = 50Hz
ƒ 6 = 60Hz
23
Rated voltage code
A
Additional electrical equipment:
ƒ O = with bare cable end
ƒ P = with plug
ƒ A = with plug and float switch
5M
Connection cable length
2.4 Scope of delivery
ƒ Pump
ƒ Installation and operating instructions
2.5 Functions
2.5.1 Self-switching thermal motor monitoring
If the motor becomes too hot, the pump is deactivated. After
the motor has cooled down, the pump is automatically
switched on again.
2.5.2 Float switch
The Rexa MINI3-V...-A is equipped with a float switch. The
float switch is used to switch the pump on and off depend-
ing on the level:
ƒ Upper floater: Pump on
ƒ Lower floater: Pump off
3 Application/use
3.1 Intended use
For the pumping in domestic areas of:
ƒ Sewage not containing faeces
Wash basins
Shower basins/bathtubs
Washing machines
ƒ Wastewater (with small amounts of sand and gravel)
Rainwater
Drainage water