en
Installation and operating instructions Wilo-Rexa MINI3 9
NOTICE!The specifications applicable to
swimming pools also apply to accessible
basins.
1.10 Removal
ƒ Wear protective equipment!
ƒ Product without plug: Have the connection
cable disconnected from the mains by a quali-
fied electrician.
ƒ Depending on the operating mode and dura-
tion, the housing parts become hotter than
40°C (104°F).
– Only touch the product by the carrying
handle.
– Allow product to cool down.
ƒ Clean the device thoroughly.
ƒ If there is a risk of germ formation, observe
the following points:
– Ensure sufficient air exchange.
– Wear a breathing protection mask e.g. 3M
Series 6000 with filter 6055 A2
– Disinfect product.
1.11 Clean and disinfect
ƒ Wear protective equipment!
The protective equipment prevents contact
with germs that are hazardous to health and
the disinfectant.
ƒ If a disinfectant is used, follow the manufac-
turer's instructions!
– Wear protective equipment according to the
manufacturer's instructions! If in doubt, ask
your specialist dealer.
– Inform all persons about the disinfectant
and how to use it correctly!
1.12 Maintenance tasks
ƒ Wear protective equipment!
ƒ Carry out maintenance work in a clean, dry and
well-lit place.
ƒ Only original parts of the manufacturer may be
used. The use of any non-original parts re-
leases the manufacturer from any liability.