EN
Transportation and storage
18
Magnetic eld
WARNING
The permanent magnet rotor inside the pump can be a
danger to life for people with medical implants during
dismantling.
Never remove the rotor.
Hot components
WARNING
Pump housing and glandless pump motor can get hot and
cause burns when touched.
During operation only touch the control module.
Allow the pump to cool down before commencing any
work.
Keep highly ammable materials away.
4 Transportation and storage
4.1 Scope of delivery
Fig.
1
and
2
4.2 Accessories
Separately available:
Thermal insulation shell (only for heating applications)
4.3 Transport inspection
Following delivery immediately check for damage and in-
tegrity. Where necessary make a complaint immediately.
4.4 Transportation and storage
Only carry motor or pump housing Fig.
4
.
Store in original packaging.
Protect against damp and mechanical load.
Dry pump thoroughly following utilisation
(e.g.function test) and store for a maximum of 6months.
Permissible temperature range: -20°C to +40°C
5 Installation
5.1 Personnel requisition
Carry out installation using qualied specialists only.
5.2 Safety
WARNING
Hot liquids can cause scalding. Before the installation or
removal of the pump or the dismantling of the housing
screws observe the following:
Close shut-off device or drain unit.
Cool down the unit completely.