Commissioning | 5 | English
Operating instructions PT Series | 89014547; 2021-03 | 29
Connecting the mains cable
Note:Select the correct cross section and number of wires in the mains cable to suit the on-site voltage and fuse
protection.
Ø Remove the front cover.
Ø Insert the mains cable (1) at the rear of the machine.
Ø Pull the mains cable (1) out at the front and guide it to the left.
Ø Strip the wire end of the mains cable and attach ferrules.
Ø Connect the mains cable wires (3) according to the connection diagram }30 and close the quick release connectors
(2).
Ø If necessary, connect the bridges (6) according to the connection diagram }30 (7) and press in firmly using a screw-
driver.
Ø Connect the green-yellow wire on the distributor to the earth wires (4).
Ø Fasten the mains cable to the strain relief on the mounting plate using a cable tie (5).
1
2
3
4
5
6 7
1
Establishing equipotential bonding
1
Ø Connect the warewasher to the on-site equipotential
bonding system.
Ø Position of the connecting screw (1) see drawing.