TSW200E1
and PCM30C frames, it is possible to simultaneously monitor and visualise the CAS state of the 30
telephone channels.
The TSW200E1 does not transmit in the Monitor mode. The connection used employs the 2
Mbps G.703 interface receive port (RX) only.
5.7.1 - MONITOR Mode Configuration
The Monitor mode has few setup parameters, for the only setup is for the G.703-2M
interface reception. The description of the parameters follows:
• PCM: see section 5.3.1
• Frame: Selects the frame to display, from 00 to 15.
• Time slot: Selects the timeslot to display in the test, from 00 to 31.
• Termination: see section 5.3.1
• Line Code: see section 5.3.1
5.7.2 - Performing the MONITOR Test
After plugging the Test Set correctly and setting up the parameters defined in the previous
item, it is possible to start the test by pressing the START/STOP key.
The following screen will be displayed:
In this screen it is possible to monitor the selected timeslot and frame data. During the test it
is possible to select another timeslot and frame to be monitored. To do this, move the cursor
appropriately with the ↑ and ↓ keys. Use the ← or → keys to change the number of timeslot or
frame.
If it is desired to visualise the status words, press <F2> (WORDS) and then the FAS, NFAS,
MFAS and NMFAS words will be displayed, as shown below.
Wise Telecommunications Industry 55