EasyManua.ls Logo

Wise TSW200E1 - Results Display; Basic Errors

Wise TSW200E1
100 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TSW200E1
<F3> (ENTER) key.
F1 F2 F3 F4
ERR TYPE ENTER AUDIO
RUNNING
BASIC ERRORS
ALARM S
HISTOGRAMS
ITU-T STANDARDS
EVENT LOG
When the CLEAR key is pressed, the test time, all counters and histograms are cleared and
the test is restarted. If the TSW200E1 was in sync, it remains in sync.
5.2 - Results display
During the TX/RX FRAMED, THROUGH FRAMED, MUX and DEMUX test modes, the
results are displayed in the following way:
an array of error and alarm counters
histograms of errors or alarms versus time
event log
For the FREQUENCY/LEVEL, MONITOR and ROUND-TRIP DELAY modes, the results
are displayed differently and will be described appropriately in the corresponding sections.
5.2.1 - Basic errors
For the E1/G.704 module, many screens display the basic errors.
The first basic errors screen is shown below.
MENU NEXT
F1 F2 F3 F4
B A S I C E R R O R S
BIT ERR = 0000000
BER = 0.00E-00
INJEC.ERR. = 0000000
RX RATE = 1920000 bps
TIME = 0000:10:26
In this screen the following test results are displayed:
BIT ERROR: this counter indicates the number of errored bits that were flagged while
the test is running.
Wise Telecommunications Industry 37

Table of Contents