TSW200E1
one kind of setup is often used, it is possible to save the setup. It can be easily loaded, thus avoiding
setting each of the parameters individually.
To save a configuration, setup the Test Set as desired and go back to the Memory screen.
After that, place the cursor in the last line and use theand keys to select the desired position.
Press <F2> (SAVE) and then all setup parameters are stored.
To load a configuration memory, choose from which memory it is desired to load using the
and keys. Next, press <F3> (LOAD) and the equipment will be set up according to the
selected memory.
6.3 - Printing Results
The test results can be printed during execution or later, from the equipment memory.
Printing can be serial or parallel, using the appropriate cable. The serial and parallel cables
are provided. For parallel printing, the user must provide a printer with adequate buffering
capability to hold the data while it is being printed, for there is no flow control.
First connect the TSW200E1 to the printer using the appropriate cable (serial or parallel) on
the back panel connector.
If it is desired to print while the test is running, it is necessary to setup printing before the
test starts. For serial printing, the data transmission rate must be chosen. Some serial
communication parameters are predetermined: 8-bit word, no parity, 1 stop bit and no flow control.
Pressing the PRINT key in any memory visualisation screen causes the TSW200E1 to
display the print management screen shown below.
EXIT PRINT
F1 F2 F3 F4
PRINT
MEMO D ATA = LAST RESU LTS
TYPE = SERIAL
TX CLOCK = 50 bps
Use the ↑ or ↓ keys to place the cursor at the appropriate line and use the ← or → keys to set
up the parameter as desired. Place the cursor at the MEMO DATA line and select the data source
(last test result, LAST, or memories 1 to 10, MEMO1 to MEMO10). After that, select the print
TYPE and the data transmission speed in TX CLK. After this, press PRINT or <F4> and the results
will be printed. To get out of this screen, press <F1> (BACK).
If on-line printing is desired, set up the equipment and go back to the setting screen for the
desired test. Start the test. While the test is running, press PRINT. Many printings can be done
during the same test. The histograms are not printed during the test, but only from the equipment
memories.
If the user has no printer, Windows HyperTerminal can be used to upload serially the results
to the computer. To do this, open the HyperTerminal (in
Start/Programs/Accessories/Communications/HyperTerminal file hypertrm.exe). Connect the