Appendix: Technical data
Ambient temperature 41°F to 95°F (5°C to 35°C)
(empty the water system in case of frost).
Maximum humidity 80 % relative humidity without condensation.
Do not use device outdoors.
Installation surface/water spray The device must be placed and leveled on
ahorizontal, sturdy, water-resistant, and
heatproof base.
The device must not be cleaned using awater
jet. The device must be installed where it is
protected against water spray. The device must
not be located on asurface that is sprayed or
cleaned with awater hose, steam jets, steam
cleaner, or similar devices.
Installation clearances
For operating, service, and safety reasons the
machine should be installed with aclearance
from the building or non-WMFcomponents of
not less than 1.97in (50mm) at the sides and
2.36in (60mm) at the back.
A minimum working space of 31.50in (800mm)
in front of the coffee machine is recommended.
Clearance of at least 7.87in (200mm) above
the product hopper is recommended. The height
of the installation surface above the floor is at
least 33.47in (850mm). If the coffee machine
connections are to be run downwards through
the counter, please make space for the lines,
which can reduce the usable space below the
machine.
Installation dimensions of the
water filter
See the User Manual for the water filter.
Installation clearances