Page #25 background imageLoading...
Page #25 background image
25
WMF presto Service manual edition 08/2007
WMF presto Service Manual
Report
Display
Descr.
Entry ring mem.
Entry display
Comment
No. malfunction
memory
130 F130 General current
malfunction
Short circuit if
immediately at
switching-on
24/30 V present
28
not implemented
149 F149 General voltage
malfunction
If short circuit is present
in 24/30V systems
86
161 F161 flowmeter
malfunction during
brewing
241
162 F162 flowmeter
malfunction during
cleaning
242
163 F163 flowmeter
malfunction during
checking
243
164 F164 flowmeter
malfunction during hot
water dosage
244
165 F165 flowmeter
malfunction during choc
dosage
24
5
166 F166 flowmeter
malfunction during DK
feeding
24
6
167 F167 flowmeter
malfunction during
descaling
167
186 F186 timeout during
steam boiler filling
24
7
187 F187 Steam boiler sensor
damage
232
188 F188 Excess temperature
in steam boiler
231