30
WMF presto Service manual edition 08/2007
WMF presto Service Manual
8.2 Setting pressure reducer
Setting pressure reducer without laptop
Start service program service routine setting
pressure reducer start.
Remove screw-cap on water tank filler.
Screw auxiliary nipple to accept plug-in connector into
the water tank filler
Mount auxiliary tool on filler.
Press field
Start
Supply valve opens
Read pressure on pressure gauge.
Set pressure to 1.8 bar at pressure reducer.
Finish test (machine is turned off).
Dismantle setting equipment and remove auxiliary
nipple.
Replace filler cap.
S
etting pressure reducer with KonfigTool
Adjust test environment set pressure reducer start
Remove filler screw-cap
Screw auxiliary nipple to accept plug-in connector into
the water tank filler.
Mount auxiliary tool on filler.
Start test on laptop
Supply valve opens
Read pressure on pressure gauge.
Set pressure to 1.8 bar at pressure reducer.
Finish test
Dismantle setting equipment and remove auxiliary
nipple.
Replace filler cap.