9 Faults
It is not possible to power
on the fan anemometer
On/Off key pressed too
fleetingly
Press the On/Off key slight-
ly longer
Batteries not inserted cor-
rectly
Battery voltage insufficient
10 Error codes
10.1 Air temperature
Temperature is below
measuring range
Acclimatize the fan anemometer at room
temperature for 30 minutes. If E02 is still
displayed, return the fan anemometer for
repair.
Temperature is above
measuring range
Acclimatize the fan anemometer at room
temperature for 30 minutes. If E02 is still
displayed, return the fan anemometer for
repair.
Temperature sensor defec-
tive
Return the fan anemometer for repair.
10.2 Relative humidity
Caused by temperature
error
Please refer to paragraph 10.1
Return the fan anemometer for relative hu-
midity calibration
Moisture sensor defective
Return the fan anemometer for repair.