7.Remote Control
Dial the number associated to the alarm main unit by phone (mobile
phone), and after one ringing cycle, you can hear a voice prompt
“Please enter password”. If the password is right, you will here “Press
1 to arm, Press 2 to disarm, Press 3 to Monitor, Press 4 to Intercom”. If
the password is wrong, you will hear a prompt voice “wrong password,
please re-enter”.
Press [1]: arm, if finished successfully, you will hear a voice prompt
“System armed”.
Press [2]: disarm, if finished successfully, you will hear a voice prompt
“System disarmed”.
Press [3]: monitoring for 30 seconds, to continue monitoring, press [3]
again to monitor for another 30 seconds.
Press [4]: two-way intercom for 30 seconds. You can’t operate the
main unit during this time.
8.Emergency Help
Press [Emergency ] button on keypad, or [ ] button on remote
controller or wireless panic button, the main unit will alarm and make
call to the preset user numbers.
9.System Dialing Function
In disarm status, you can use the main unit to make any call just like a
land-line telephone. Dial telephone number on keypad, press [ ]
button, the main unit will make a beep and the [Signal] indicator will be
flashing. After the call, press [ ] button again, the main unit will be in
disarm status.
10.Alarming Record Checking
In disarm state, input [*0#], then the main unit will make a long beep
and enters the state of alarm record checking. After displaying the
alarm and defense zone number indicator, the LCD screen will display
the exact alarming time of this defense zone. Press 2, you can upturn
to check the previous alarming record; press 8, downturn to check; and
press [*#] to exit checking.
Care and Maintenance
22
21
Care and Maintenance
For example: the 51st defense zone; the 7th alarming; alarming time:
12:10, August 1st, 2008. LCD display for one second,
and then display the alarming time:
You can also check the alarm records by SMS (Max: Latest 9 records).
SMS Check Command: Remote Control Password (Default: 1234) + [3]
Reply SMS:
Eg: Alarm record:
NO1 Zone: 05 TIME: 11-06-25 11:37
(It indicates the first record: wireless zone 5 alarm time)
…………….
NO9 Zone: 19 Time: 11-06-25 11:45
(It indicates the first record: wireless zone 19 alarm time)
11.GSM Signal Checking
Before installing the main unit, you should check the signal of the
installing place in order to ensure the unit can perform well. In setup
state, input [81] #, the main unit will make a long beep and display
00+XX (XX indicates the intensity of the signal). And the intensity
should be within the range of 07-31; if it’s less than 07, you should
change place.
This icon indicates the signal intensity. When the intensity number is
0-7, this icon will not be shown; when it’s 8-15, this icon will be
flashing; when the number is larger than 16, this icon will be on the
screen without flash.
For example: if the signal intensity is 12, it will display as: