CSO24 and CSO30 (SWS #13508346)
Component Removal
4-2
#9001333 - Revision A - August, 2014
COMPONENT ACCESS AND REMOVAL
This section explains how to access and remove components in a CSO24 and CSO30 unit. An attempt has been
made to arrange these procedures in such a way as to simulate which components would need to be removed first
in order to gain access to other components. When following a component removal procedure, it may be necessary
to reference another component removal procedures listed earlier in this section.
NOTE: Before continuing, please take note of the WARNINGS and CAUTION below.
• TO AVOID ELECTRIC SHOCK OR DEATH, POWER TO UNIT MUST BE DISCONNECTED WHENEVER
ACCESSING AND/OR REMOVING COMPONENTS POWERED BY ELECTRICITY OR COMPONENTS NEAR
OTHER ELECTRICAL COMPONENTS.
• IF NECESSARY TO REMOVE THE APPLIANCE FROM ITS INSTALLATION, REMEMBER THAT IT IS HEAVY
AND COULD TIP AND/OR FALL, RESULTING IN SERIOUS INJURY.
Be careful when handling sheet metal parts - Edges may be sharp.
Tools Needed
• 6-Lobe Torx Type Drivers - Sizes: T-10, T15, T-20
• Metric Socket Set: 6mm - 13mm
• Knife (to cut insulation when replacing bottom heating element)
• Pliers: (Regular, Needle-nose, Side Cutter)
• Gloves (to protect hands from cuts)
• Multimeter
• Cleaning Rags