EasyManua.ls Logo

Wolf TGB-40 - Changing the Output

Wolf TGB-40
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
General
Theheating output will be determinedby the fan
speed. You can modify the heating output by
changing the fan speed in accordancewith the
setting valueslisted in table "Output adjustment".
Lower output limit
. Press both programming keys (+) and (-)
simultaneously;the displaywill show "a.".
. With key(+)selectparameter no. 2forthe lower
output Iimit.
. Pressresetkey;the factory-set parametervalue
accordingto thetablebelowwiIIthenbedisplayed.
. Changethe parameterwith the (+) or (-) key.
. Pressthe reset key; the modified value will be
adopted, and the display will again show the
heatingwater flow temperature.Thisterminates
the adjustment of the lower output.
Upper output limit
. Press both programming keys (+) and (-)
simultaneously;the displaywill show "a.".
. With key(+),selectparameter no. 3forthe upper
output limit of DHW cylinder loading or
parameter no. 4 for heating mode.
. Pressresetkey;the factory-set parametervalue
accordingtothetable belowwill thenbedisplayed.
. Changethe parameterwith the (+) or (-) key.
. Pressthe reset key; the modified value will be
adopted and the display will again show the
heatingwater flow temperature.Thisterminates
the adjustment of the upperoutput.
Changingthe output
Resetbutton
(-) (+)
Programmingkeys
Fig.: Control unit display
Table: Output adjustment TGB-40
Table:
Output adjustment TGB-60
~ -eating
23

Other manuals for Wolf TGB-40

Related product manuals