OPERATION
Blade Installation
3
3-18 EGdoc022715 Operation
3.5 Blade Installation
Multirip Option
The main shaft’s strength and motor horsepower allows you to use maximally five blades with your
Edger. Never use more than five blades! The standard Wood-Mizer Edger is equipped with two
blades. The additional three blades in Edger are installed on the provided bushing with spacers.
The blades should be installed on the main shaft in the following order:
movable blade arbor,
fixed blade arbor,
bushing with three blades.
NOTE: It is necessary to adjust the movable blade limit switch after installing the bushing with
additional blades. To do that, measure the distance from the left edge of the fixed blade arbor to the
left edge of the bushing with additional blades (see the figure below). Then loosen the screws and
move the limit switch left, the measured distance.
WARNING! Failure to adjust the safety switch after installing additional
blades may result in machine damage.