Setup & Operation
Control Setup
Setup & Operation 60AS207doc032519 1-8
1
Units. This setting allows you to choose what unit of measure to use for your Blade
Height and Increment Settings. The default value is Fractional Inches (1/32”). You can
change the Unit Of Measure to Decimal Inches (.0313”) or Millimeters (1 mm). Push the
Save button to store the new Unit Of Measure setting. To return to the previously stored
Unit Of Measure, push Exit and turn the key switch to the off (#0) position.
See Figure 1-7.
PID (Proportional - Integral - Differential) Values. These settings allow a technician to
diagnose and fine-tune the Accuset control for various environmental factors. These set-
tings are made at the factory and should not normally need adjusting by the operator.
See Table 1-2. The factory default PID value settings are shown below. Alternate set-
tings are provided for use with LT70E25 electric sawmills.
After making the desired PID Value adjustments, push the Save button and go to the
desired Accuset mode. Test how the changes affect Accuset performance. If the new set-
tings cause undesirable results, reset Accuset to the factory defaults (See Section 1.1.4
).
FIG. 1-7
Value Factory Default Alternate for LT70 E25
Up Ticks 15
Up Distance 7500 17000
Up Minimum 50 2
Down Ticks 15
Down Distance 5000 17000
Down Minimum 50 2
TABLE 1-2
3H0989-6
UNIT OF MEASURE
Decimal
Fractional Millimeter Exit
6 - 3/4