37483C
Config
urati
on
Soft
ware Version 2
.0
xx
x
Manual 37483C
DTSC
-
2
00
ATS Controll
er
2
Table of Contents
Default Chapter
3
Table of Contents
3
Chapter 1. General Information
8
Table 1-1: Manual - Overview
8
• the List of Parameters (Appendix B) Is Updated. for Details See Page 143 Ff.
8
Chapter 2. Configuration
9
Configuration Via the Front Panel
9
Configuration Via PC
10
Install Toolkit Configuration and Visualization Software
10
Install Toolkit Software
10
Install Toolkit Configuration Files
11
Starting Toolkit Software
12
Configure Toolkit Software
13
Connect Toolkit and the DTSC-200 Unit
14
View DTSC-200 Data with Toolkit
16
Figure 2-1: Toolkit - Visualization Screen
16
Figure 2-2: Toolkit - Analog Value Trending Screen
16
Configure the DTSC-200 with Toolkit
17
Figure 2-3: Toolkit - Configuration Screen
17
General Information
18
Important Designations
18
Signal and Command Abbreviations
18
Monitoring Functions
19
Function of the Inputs and Outputs
20
Chapter 3. Parameters
22
Language
23
Password
23
Event History
24
Figure 3-1: Event History- Display
24
Measuring
25
Measuring: Rated Values
25
Measuring: Transformers
29
Application
31
Application: Application Mode
31
Application: Transfer Timers
32
Figure 3-2: Source Stable and Outage Timers
37
Application: Transfer Logics (Logicsmanager)
38
Figure 3-3: External Timer Bypass - Push Button
40
Application: Elevator Pre-Signal
42
Figure 3-4: Elevator Pre-Signal - Example 1
43
Figure 3-5: Elevator Pre-Signal - Example 2
43
Figure 3-6: Elevator Pre-Signal - Example 3
43
Application: Motor Load Disconnect
44
Application: Source Priority Selection
45
Figure 3-7: Source Priority Selection - S1 Preferred
46
Figure 3-8: Source Priority Selection - S2 Preferred
46
Table 3-1: Application - Load Shed with Standard Transition Switch
49
Figure 3-9: Load Shed Relay Wiring - Standard Transition Switch
50
Figure 3-10: Load Shed Relay Wiring - Delayed or Closed Transition Switch
50
Table 3-2: Application - Load Shed with Delayed or Closed Transition Switch
50
Breaker
52
Breaker: Transfer Switch Type
52
Figure 3-11: Open Transition Switch - Connected to Source 1
52
Figure 3-12: Open Transition Switch - Connected to Source 2
52
Figure 3-13: Delayed Transition Switch - Connected to Source 1
53
Figure 3-14: Delayed Transition Switch - Neutral Position
53
Figure 3-15: Delayed Transition Switch - Connected to Source 2
53
Figure 3-16: Closed Transition Switch - Connected to Source 1
54
Figure 3-17: Closed Transition Switch - Neutral Position
54
Figure 3-18: Closed Transition Switch - Connected to Source 1 and 2 (Overlap Position)
54
Figure 3-19: Closed Transition Switch - Connected to Source 2
54
Figure 3-20: Breaker - Transition Pulse
58
Test Modes
61
Timer Exerciser
62
Figure 3-21: Test Modes - Load Test Configured for Timer Exerciser
62
Figure 3-22: Test Modes - No-Load Test Configured for Timer Exerciser
62
Figure 3-23: Test Modes - Parameter Ids of the Timer Exercisers
63
Figure 3-24: Test Modes - Configuring Exerciser 1 for a Daily Exercise
64
Figure 3-25: Test Modes - Configuring Exerciser 2 for a Weekly Exercise
64
Figure 3-26: Test Modes - Configuring Exerciser 3 for a 14-Day Exercise
64
Figure 3-27: Test Modes - Configuring Exerciser 4 for a One Event Exercise
65
Figure 3-28: Test Modes - Display Screen with Pending Exercise Event
65
Figure 3-29: Test Modes - Display Screen with Running Load Test
65
Monitoring
66
Monitoring: Alarm Acknowledgement
66
Monitoring: Limit Switch Monitoring
66
Monitoring: Source 1 Monitoring
67
Monitoring: Source 2 Monitoring
72
Monitoring: In-Phase Monitoring (Synch Check)
77
Figure 3-30: Inphase Monitoring
77
Figure 3-31: Switch Reaction Time
82
Monitoring: Overcurrent
86
Figure 3-32: Monitoring - Load Time-Overcurrent
86
Table 3-3: Monitoring - Standard Values - Load Time-Overcurrent
86
Monitoring: Overload
88
Figure 3-33: Monitoring - Overload
88
Table 3-4: Monitoring - Standard Values - Overload
88
Monitoring: Engine, Start Failure Source 1
90
Monitoring: Engine, Start Failure Source 2
90
Monitoring: Battery, Overvoltage
91
Figure 3-34: Monitoring - Battery Overvoltage
91
Table 3-5: Monitoring - Standard Values - Battery Overvoltage
91
Monitoring: Battery, Undervoltage
93
Figure 3-35: Monitoring - Battery Undervoltage
93
Table 3-6: Monitoring - Standard Values - Battery Undervoltage
93
Monitoring: Canopen Interface
95
Discrete Inputs
96
Figure 3-36: Discrete Inputs - Control Inputs - Operation Logic
96
Table 3-7: Discrete Inputs - Assignment
96
Table 3-8: Discrete Inputs - Parameter Ids
97
Table 3-9: External Discrete Inputs - Parameter Ids
97
Discrete Outputs (Logicsmanager)
98
Table 3-10: Relay Outputs - Assignment
98
Table 3-11: Discrete Outputs - Parameter Ids
99
Table 3-12: External Discrete Outputs - Parameter Ids
99
Counters
100
Configure Counters: Operation Hours, Kwh, and Kvarh
100
Logicsmanager
102
Logicsmanager: Internal Flags
102
Table 3-13: Internal Flags - Parameter Ids
102
Logicsmanager: Timer
103
Interfaces
105
Interfaces: CAN Bus (Flexcan)
105
Figure 3-37: Interfaces - Principle of PDO Mapping
108
Interfaces: Serial Interface 1 (RS-232)
113
Interfaces: Serial Interface 2 (RS-485)
113
System
114
System: Configure Display Backlight
114
System: Configure Daylight Saving Time
115
Table 3-14: Daylight Saving Time - Configuration Example
115
Table 3-15: Daylight Saving Time - Examplary Dates
115
System: Password System
117
System: Real-Time Clock Set
119
System: Versions
120
Figure 3-38: Logicsmanager - Function Overview
122
Table 3-16: Logicsmanager - Command Overview
122
Figure 3-39: Logicsmanager - Display in Toolkit
123
Figure 3-40: Logicsmanager - Display in LCD
123
Logical Symbols
123
Table 3-17: Logicsmanager - Logical Symbols
123
Logical Outputs
124
Logical Outputs: Internal Flags
124
Logical Outputs: Internal Functions
124
Logical Outputs: Relay Outputs
125
Logical Command Variables
126
Logical Command Variables: [00.00] - Internal Flags
126
Logical Command Variables: [01.00] - Alarm Classes
127
Logical Command Variables: [03.00] - Engine Control
127
Logical Command Variables: [04.00] - Operating Status
128
Logical Command Variables: [06.00] - Load Alarms
128
Logical Command Variables: [08.00] - System Alarms
129
Logical Command Variables: [09.00] - Discrete Inputs
129
Logical Command Variables: [11.00] - Time Functions
130
Logical Command Variables: [12.00] - External Discrete Inputs (Expansion Board)
130
Logical Command Variables: [13.00] - Internal Relay Output Status
131
Logical Command Variables: [14.00] - External Relay Outputs Status
131
Logical Command Variables: [19.00] - ATS Status Flags
132
Logical Command Variables: [20.00] - ATS Status Flags
132
Logical Command Variables: [21.00] - ATS Alarms
133
Logical Command Variables: [98.00] - Logicsmanager Outputs
133
Factory Setting
134
Factory Setting: Functions
134
Factory Setting: Relay Outputs
139
Factory Setting: Internal Flags
141
Discrete Inputs
142
Product Service Options
153
Returning Equipment for Repair
153
Packing a Control
154
Return Authorization Number RAN
154
Replacement Parts
154
How to Contact Woodward
155
Engineering Services
156
Technical Assistance
157
Other manuals for Woodward DTSC-200
Manual
141 pages
Operation Manual
33 pages
Installation Manual
41 pages
5
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the Woodward DTSC-200 and is the answer not in the manual?
Ask a question
Woodward DTSC-200 Specifications
General
Number of Digital Inputs
16
Approvals
CE
Input Voltage Range
24V DC
Communication Interface
Ethernet
Actuation
Electro-hydraulic, electro-mechanical
Related product manuals
Woodward DTSC-200A
37 pages
Woodward DSLC-2
226 pages
Woodward UG-8 Dial
62 pages
Woodward UG-10 Dial
62 pages
Woodward DPG-2201-002
50 pages
Woodward DPG-2201-00 Series
50 pages
Woodward DPG-2223-00 Series
58 pages
Woodward 2301A
52 pages
Woodward UG-25+
60 pages
Woodward 723 PLUS
70 pages
Woodward GCP-30 Series
179 pages
Woodward MicroNet Simplex
130 pages