Home
Woodward
Controller
DTSC-200
Woodward DTSC-200 User Manual
5
of 1
of 1 rating
141 pages
Give review
Manual
Specs
To Next Page
To Next Page
Loading...
37386D
Config
urati
on
Soft
ware Version 1.0
00
8
Manual 37386D
DTSC
-
2
00
ATS Controll
er
2
Table of Contents
Default Chapter
3
Table of Contents
3
Chapter 1. General Information
8
Table 1-1: Manual - Overview
8
Chapter 2. Configuration
9
Configuration Via the Front Panel
9
Configuration Using the PC
10
General Information
11
Important Designations
11
Signal and Command Abbreviations
11
Monitoring Functions
12
Function of the Inputs and Outputs
13
Chapter 3. Parameters
15
Language
16
Password
16
Event History
17
Figure 3-1: Event History- Display
17
Measuring
18
Measuring: Rated Values
18
Measuring: Transformers
22
Application
24
Application: Application Mode
24
Application: Transfer Timers
25
Figure 3-2: Source Stable and Outage Timers
28
Application: Transfer Logics (Logicsmanager)
29
Figure 3-3: External Timer Bypass - Push Button
31
Application: Elevator Pre-Signal
33
Figure 3-4: Elevator Pre-Signal - Example 1
34
Figure 3-5: Elevator Pre-Signal - Example 2
34
Figure 3-6: Elevator Pre-Signal - Example 3
34
Application: Motor Load Disconnect
35
Application: Source Priority Selection
36
Figure 3-7: Source Priority Selection - S1 Preferred
37
Figure 3-8: Source Priority Selection - S2 Preferred
37
Table 3-1: Application - Load Shed with Standard Transition Switch
40
Figure 3-9: Load Shed Relay Wiring - Standard Transition Switch
41
Figure 3-10: Load Shed Relay Wiring - Delayed or Closed Transition Switch
41
Table 3-2: Application - Load Shed with Delayed or Closed Transition Switch
41
Breaker
42
Breaker: Transfer Switch Type
42
Figure 3-11: Open Transition Switch - Connected to Source 1
42
Figure 3-12: Open Transition Switch - Connected to Source 2
42
Figure 3-13: Delayed Transition Switch - Connected to Source 1
43
Figure 3-14: Delayed Transition Switch - Neutral Position
43
Figure 3-15: Delayed Transition Switch - Connected to Source 2
43
Figure 3-16: Closed Transition Switch - Connected to Source 1
44
Figure 3-17: Closed Transition Switch - Neutral Position
44
Figure 3-18: Closed Transition Switch - Connected to Source 1 and 2 (Overlap Position)
44
Figure 3-19: Closed Transition Switch - Connected to Source 2
44
Figure 3-20: Breaker - Transition Pulse
47
Test Modes
50
Monitoring
51
Monitoring: Alarm Acknowledgement
51
Monitoring: Limit Switch Monitoring
51
Monitoring: Source 1 Monitoring
52
Monitoring: Source 2 Monitoring
57
Monitoring: In-Phase Monitoring (Synch Check)
62
Figure 3-21: Inphase Monitoring
62
Figure 3-22: Switch Reaction Time
65
Table 3-3: Calculation of the Phase Angle Deviation
66
Monitoring: Overcurrent
68
Figure 3-23: Monitoring - Load Time-Overcurrent
68
Table 3-4: Monitoring - Standard Values - Load Time-Overcurrent
68
Monitoring: Overload
70
Figure 3-24: Monitoring - Overload
70
Table 3-5: Monitoring - Standard Values - Overload
70
Monitoring: Engine, Start Failure Source 1
72
Monitoring: Engine, Start Failure Source 2
72
Monitoring: Battery, Overvoltage
73
Figure 3-25: Monitoring - Battery Overvoltage
73
Table 3-6: Monitoring - Standard Values - Battery Overvoltage
73
Monitoring: Battery, Undervoltage
75
Figure 3-26: Monitoring - Battery Undervoltage
75
Table 3-7: Monitoring - Standard Values - Battery Undervoltage
75
Monitoring: Canopen Interface
77
Discrete Inputs
78
Figure 3-27: Discrete Inputs - Control Inputs - Operation Logic
78
Table 3-8: Discrete Inputs - Assignment
78
Table 3-9: Discrete Inputs - Parameter Ids
79
Table 3-10: External Discrete Inputs - Parameter Ids
79
Discrete Outputs (Logicsmanager)
80
Table 3-11: Relay Outputs - Assignment
80
Table 3-12: Discrete Outputs - Parameter Ids
81
Table 3-13: External Discrete Outputs - Parameter Ids
81
Counters
82
Configure Counters: Operation Hours, Kwh, and Kvarh
82
Logicsmanager
83
Logicsmanager: Internal Flags
83
Table 3-14: Internal Flags - Parameter Ids
83
Logicsmanager: Timer
84
Interfaces
86
Interfaces: CAN Bus (Flexcan)
86
Figure 3-28: Interfaces - Principle of PDO Mapping
89
Interfaces: Serial Interface 1 (RS-232)
94
Interfaces: Serial Interface 2 (RS-485)
94
System
95
System: Configure Display Backlight
95
System: Configure Daylight Saving Time
96
Table 3-15: Daylight Saving Time - Configuration Example
96
System: Password System
97
System: Real-Time Clock Set
99
System: Versions
100
Logicsmanager
101
Figure 3-29: Logicsmanager - Function Overview
102
Table 3-16: Logicsmanager - Command Overview
102
Logical Symbols
103
Figure 3-30: Logicsmanager - Display in Leopc
103
Figure 3-31: Logicsmanager - Display in LCD
103
Table 3-17: Logicsmanager - Logical Symbols
103
Logical Outputs
104
Logical Outputs: Internal Flags
104
Logical Outputs: Internal Functions
104
Logical Outputs: Relay Outputs
105
Logical Command Variables
106
Logical Command Variables: [00.00] - Internal Flags
106
Logical Command Variables: [01.00] - Alarm Classes
107
Logical Command Variables: [03.00] - Engine Control
107
Logical Command Variables: [04.00] - Operating Status
108
Logical Command Variables: [06.00] - Alarms of the Load
108
Logical Command Variables: [08.00] - Alarms of the System
109
Logical Command Variables: [09.00] - Discrete Inputs
109
Logical Command Variables: [11.00] - Time Functions
110
Logical Command Variables: [12.00] - External Discrete Inputs (Expansion Board)
110
Logical Command Variables: [13.00] - Status of the Internal Relay Outputs
111
Logical Command Variables: [14.00] - Status of the External Relay Outputs
111
Logical Command Variables: [19.00] - ATS Status Flags
112
Logical Command Variables: [20.00] - ATS Status Flags
112
Logical Command Variables: [21.00] - ATS Alarms
113
Logical Command Variables: [98.00] - Logicsmanager Outputs
113
Factory Setting
114
Factory Setting: Functions
114
Factory Setting: Relay Outputs
119
Factory Setting: Internal Flags
121
Discrete Inputs
122
Appendix B. Geteventlog
123
Geteventlog Software
123
Installing Geteventlog
123
Starting Geteventlog
123
Figure 3-32: Geteventlog - Interface Configuration
123
Figure 3-33: Geteventlog - Event Logger Content
124
Figure 3-34: Geteventlog - Event Logger Content in Excel
124
Resetting the Event Logger
125
Table 3-18: Event Logger - Event Texts and Numbers
125
Appendix C. List of Parameters
126
Appendix D. Service Options
136
Product Service Options
136
Returning Equipment for Repair
136
Packing a Control
137
Return Authorization Number RAN
137
Replacement Parts
137
How to Contact Woodward
138
Engineering Services
139
Technical Assistance
140
Other manuals for Woodward DTSC-200
Configuration Manual
158 pages
Operation Manual
33 pages
Installation Manual
41 pages
5
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the Woodward DTSC-200 and is the answer not in the manual?
Ask a question
Woodward DTSC-200 Specifications
General
Number of Digital Inputs
16
Approvals
CE
Input Voltage Range
24V DC
Communication Interface
Ethernet
Actuation
Electro-hydraulic, electro-mechanical
Related product manuals
Woodward DTSC-200A
37 pages
Woodward DSLC-2
226 pages
Woodward UG-8 Dial
62 pages
Woodward UG-10 Dial
62 pages
Woodward DPG-2201-002
50 pages
Woodward DPG-2201-00 Series
50 pages
Woodward DPG-2223-00 Series
58 pages
Woodward 2301A
52 pages
Woodward UG-25+
60 pages
Woodward 723 PLUS
70 pages
Woodward GCP-30 Series
179 pages
Woodward MicroNet Simplex
130 pages