Do you have a question about the Woodward easYgen-3000 Series and is the answer not in the manual?
Model | easYgen-3000 Series |
---|---|
Category | Control Unit |
Display | Graphical LCD |
Communication | CAN, Ethernet, RS-485 |
Inputs | Digital and Analog |
Outputs | Relay and Analog |
Operating Temperature | -40°C to +70°C |
DC System | 24 V DC |
Protection | Over/Under Voltage, Over/Under Frequency, Reverse Power |
Synchronization | Automatic |
Operating Temperature Range | -40°C to +70°C |
Protection Class | IP20 |
Relay Outputs | Configurable relay outputs |
Digital Inputs | Configurable digital inputs |
Analog Inputs | Configurable analog inputs |
Analog Outputs | Configurable analog outputs |
Provides an overview of the manual's content and purpose.
Details precautions to protect electronic components from static damage during handling.
Discusses the application of the easYgen-3000 in marine environments and relevant considerations.
Describes the plastic housing for front panel flush mounting with a graphical display.
Describes the sheet metal housing for switch cabinet back mounting.
Indicates that detailed diagrams are available on subsequent pages.
Details the power supply connection requirements and warnings for protective earth.
Explains the charging alternator input/output functionality and connections.
Details various configurations for measuring generator voltage.
Details various configurations for measuring mains voltage.
Details busbar voltage measurement configurations.
Details connections for measuring generator current.
Details connections for measuring mains current.
Explains how to configure and measure ground current.
Explains power measurement values and defines power factor.
Details the MPU (Magnetic Pickup Unit) principle and connections.
Details signal polarity, positive/negative signals, and operation logic for discrete inputs.
Details relay outputs and their assignments with LogicsManager.
Details wiring and assignments for two-pole, single-pole, and combined analog inputs.
Explains controller configuration for analog output signals.
Details RS-485, RS-232, and CAN bus interfaces, shielding, topology, and troubleshooting.
Specifies maximum CAN bus length based on baud rate.
Provides technical data for voltage measurements.
Provides technical data for current measurements.
Lists ambient conditions like power supply, pollution degree, and insulation.
Details discrete input/output voltage ranges and contact materials.
Details analog input/output resolution, accuracy, and versions.
Details magnetic pickup input impedance and voltage.
Details vibration and shock resistance specifications and standards.
Details temperature ranges and humidity specifications.
Lists marine environmental categories.
Details accuracy specifications for frequency, voltage, current, power, and power factor.
Details accuracy specifications for analog inputs.
Lists reference conditions required for accurate measurements.
Lists suitable D-Sub connector housings for compatibility.
Provides CAN bus pin assignments for D-SUB DE9, RJ45/8P8C, and IDC connectors.