If the Delta P is high on the Woodward Controller, it may be due to an improperly configured warning threshold or the pressure regulator being adjusted too high. Configure the warning threshold for a value appropriate to the application and adjust the pressure regulator.
A
Amanda MitchellAug 23, 2025
What to do if Woodward Controller input voltage is low?
T
tiffany81Aug 23, 2025
If the Woodward Controller's input voltage is low, the cause may be a faulty battery or supply, a faulty or missing battery charger, or improper wiring. Check the battery or supply for correct operation. Also, check the battery charger for correct operation and inspect the wiring for correct size, length, contacts, and fuses.
W
wgatesAug 25, 2025
What causes high input voltage on Woodward TecJet 110 Controller?
P
Patricia HarmonAug 26, 2025
If the Woodward Controller's input voltage is high, it may be due to a faulty battery or supply, a faulty or missing battery charger, or improper wiring. Check the battery or supply for correct operation. Also, check the battery charger for correct operation and inspect the wiring for correct size, length, contacts, and fuses.
W
williamwyattAug 27, 2025
What causes Fuel Gas Pressure High on Woodward TecJet 110?
W
William GarzaAug 27, 2025
A high fuel gas pressure in the Woodward Controller may be due to an improperly configured warning threshold, a pressure regulator adjusted too high, or a faulty or slow pressure regulator. To resolve this, configure the warning threshold to a value appropriate for the application, adjust the pressure regulator, and verify the proper operation of the pressure regulator.
C
Catherine ColemanAug 27, 2025
Why is Fuel Gas Pressure Low on Woodward TecJet 110?
D
Dr. Jason VazquezAug 28, 2025
Low fuel gas pressure in the Woodward Controller can occur due to an improperly configured warning threshold or an improper engine shutdown sequence. To fix this, configure the warning threshold for a value appropriate to the application and the elevation of the site, and verify the proper engine shutdown sequence.
K
Kevin AllenAug 29, 2025
What causes Analog Flow Demand High on Woodward TecJet 110 Controller?
R
Ricky FlynnAug 29, 2025
If the analog flow demand is high on the Woodward Controller, it could be due to an analog input wiring problem or the analog input current being out of range. Check the analog input wiring for shorts, open connections, and intermittent contacts. Ensure that the analog input signal is within the configured range. The service tool displays the analog input current and the range limits.
C
Caroline ShieldsSep 13, 2025
What to do if Electronics Temperature is High on Woodward TecJet 110 Controller?
T
Tony ReedSep 13, 2025
If the electronics temperature is high in the Woodward Controller, it indicates an internal fault. Replace the valve.
B
Breanna WhiteSep 10, 2025
What does Delta P Low mean on Woodward Controller?
P
Patricia HoSep 12, 2025
If the Delta P is low on the Woodward Controller, it could be due to an improperly configured warning threshold or the valve being installed backwards. Configure the warning threshold for a value appropriate to the application and verify that the gas flow is in the direction of the arrow on the valve.
D
dukejessicaSep 7, 2025
What does Fuel Gas Temperature Low indicate on Woodward TecJet 110 Controller?
C
cookeheatherSep 7, 2025
If the fuel gas temperature is low in the Woodward Controller, it could be due to an improperly configured warning threshold or the fuel temperature being below the warning threshold. Configure the warning threshold for a value appropriate to the application and correct the fuel temperature problem.
G
guzmandanaSep 4, 2025
What causes Electrical Temperature High on Woodward Controller?
K
Kimberly BrownSep 4, 2025
If the electrical temperature is high in the Woodward Controller, it could be due to the valve ambient temperature being too high or an internal fault. Reduce the ambient temperature. If the problem persists, replace the valve.