Page.78.
negative pole -, otherwise will damage the tester.
Note: While the cable tracer tester is receiving the audio signal from the tester, it may be
influenced by other signals and make some noise.
3.3.23 TDR cable test ( *Optional )
Note: The testing cable can’t be connected to any equipment; otherwise it will damage the
tester!
Connect Alligator clip cable to the TDR port, and the cable must connect well before testing, otherwise
it will influence the accuracy. Click to enter, and click “Start” to test
Built-in BNC cable, network cable, RVV control cable, Telephone line and TVVB cable etc can test. 11
groups user-defined cable can be set.
Click “Cable” “Type” to select cable and start testing. One tap on “Start” , do one testing. If select built
in cable type for testing, click +” and“-” to adjust cable’s wave speed .