8. Typical Application
9. Connection
01
TPYICAL APPLICATION AND CONNECTION
Cat5e/6 Cable Performance Guide
MX-0404-PP
0ft 328ft32ft 65ft 98ft 131ft 164ft 197ft 230ft 262ft 295ft
0m 100m
10m
20m 30m 40m 50m 60m 70m 80m 90m
Cat5e Wiring Guide
The quality of termination for every RJ45 is essential. Poor terminations
leads to intermittent performance and
longer install times.
Key
cat 5e/6
70m/230ft
hdmi
rs232
ir tx
ir rx
Key
cat 5e/6
70m/230ft
hdmi
rs232
ir tx
ir rx
HDMI Source
Cat5e/6 (up to 70m / 230ft)
display 1
Control
System
(additional
control
via
RS232)
IR emitter placed over
or near device infared sensor
IR receiver and IR emitter placed
discretely on the display with a clear line
of sight to the remote handset being used
12v mains
rs232 to
display
(optional)
12v DC
Power
Output
01
RX-1utp-ir-70 RX-1utp-ir-70 RX-1utp-ir-70
RX-1utp-ir-70
Mirror
of 01
Mirror
of 02
Mirror
of 03
Mirror
of 04
Output
02
Output
03
Output
04
POwer
control
system
ir rx
ir link cable
02
04
07
05
06
08
Control
System
Satellite/CablE APPLE TVBlu-ray/DVD MEDIA SERVER
IR RX LINK Cable
connecting from Control
System to IR RX port of
matrix
Control
System
03