IR Matrix – Allows the IR RX port assignment to be
changed. Default is IR RX Port #1 sent to UTP output #1
etc...
Select the
button to check current settings attached to the IR port.
Com Connect State - Shows if the matrix is
connected or disconnected to the Com Port and
communication is enabled. Selection between ports is
available by pressing the Com Port Select button.
When connected, the only option will be to Disconnect
and vice versa. Press to connect/disconnect the matrix
from the software control.
• Connected for matrix communication enabled
• Disconnected for matrix communication disabled
Com Select
Connect/Disconnect
Click the Com Select dropdown to see all Com ports
available. Select your chosen Com port number and press
the CONNECT button. You will notice the button change
toshow ‘disconnect’ and CONNECT STATE change
to green for ‘connected’. Pressing the button again will
disconnect the Com port and the CONNECT state will
show red.
Input/Output Switch - Switches connected inputs
per output.
5
6
7
8
7
8
9
Operation as with remote control handset – select the
chosen input to be displayed on each output by either
clicking the left/right arrow buttons to scroll through inputs
numerically, or pressing the input number 1-4.
iii. LAN Control
The matrix can also be controlled via LAN over a network/
web browser using the supplied WyreStorm software
or LAN protocols from third party companies, such as
Control 4.
Depending on your version of matrix, LAN control
software will either be NET CTL on matrix version 1.0 or
SmartSet Gui on matrix versions 2.0, 3.0, 3.0L.
Matrix versions 2.0 and above will not be able to support
NET CTL software and features such as access through
a web browser. Please ensure you are using the correct
software for your matrix model. If in any doubt, contact
your authorised WyreStorm representative for more
information.
Attention Use a ‘straight through’ ethernet cable
for switch/router connection and a ‘cross-over’
cable for connection to a PC. Using the incorrect
cable will not damage your equipment, but it may
result in poor/no connection. Make sure that
your LAN cable is correctly terminated and firmly
connected to ports before running the software.
a. NET CTL (Matrix model ver. 1.0 only)
As with COM CTL, install the NET CTL software included
with the matrix (also downloadable from www.wyrestorm.
com) and run the program by double-clicking NETCTL.
exe
On initial opening, the program will first create a NETCTL.
TXT file that will serve as a device backup for future use;
including connection settings such as IP address and
MAC address of the matrix, as well as its name if you
decide to change the name of your matrix (see Device
Name section below).
On subsequent openings, NETCTL will then search the
Matrix for the saved data required for connection.
ADVANCED OPERATION