Do you have a question about the X-Tronic PX-70 and is the answer not in the manual?
Method for adjusting and setting voltage output levels on the power supply.
Default mode where the supply outputs a set voltage, switching to CC if current limit is met.
Mode where the supply maintains a set current, adjusting voltage as needed.
Protection feature that shuts down output when current exceeds a set limit, then retests.
Protection feature that shuts down output once when current exceeds a set limit.
| Power Consumption | 160 Watts |
|---|---|
| Input Voltage | AC 110V 60Hz |
| Constant Output Voltage Range | 0-30V Continuously Adjustable |
| Constant Output Current Range | 0-5A Continuously Adjustable |
| Output Current Protection (OCP) Current Value | 0-5A |
| Power Cord | USA Type B - 3-pin Grounded Plug |
| Working Environment | 32°F ~ 104°F / 0°C ~ 40°C |
| Storage Environment | -4°F ~ 158°F / -20°C ~ 70°C |
| Storage Humidity | 35% - 45% |
| Temperature Coefficient | <0.1% +5mA |
| Read Back Temperature Coefficient | <100 ppm + 5 mA |
| Voltage Resolution | 0.01V |
| Voltage Output Accuracy | ±0.02V |
| Current Resolution | 1 mA |
| Current Output Accuracy | <0.1 +3 mA |
| Recovery Time | 100uS |
| Ripple | < 3mArms |
| Read Back Accuracy | 1 mA |
| OCP Accuracy | 0.01A |
| Signal test frequency range | 30~1800MHZ (including cell phone signal test) |
| Dimensions | 7.25 L x 4.5” W x 9.0” H |
|---|---|
| Weight | 9.5 lbs |