Warning Messages
For error code :
the display screen and the alarm will turn off after 30 seconds
after a five-minute shutdown delay, the unit will immediately
stop inverting
For error codes  to :
the unit will stop inverting
 Low battery voltage detected
depending on setting, see
“Operating Limits” on page 18.
Inverting Check battery status and recharge if necessary.
Check for proper DC cable sizing.
Check for loose connections and tighten if necessary.
 AC output overload warning Inverting Reduce the loads connected to the AC outlet of the unit.
 Over-temperature warning Inverting Reduce the loads connected to the AC outlet of the unit.
Check that the ventilation grille is not blocked.
Check for ambient temperature and move the unit to a cooler
location whenever possible.
 not used
 not used
Table 3
Error Codes Displayed on the Display Panel Screen
Error Code Condition Mode Action