31 Freedom Xi Owners Guide
Specifications
NOTE: Specifications are subject to change without prior notice.
Physical Specifications Freedom Xi 1000 Freedom Xi 2000
L × W × H 19.2” (487mm) × 9.4” (240mm)× 4.7” (120mm) 19.2” (487mm) × 9.4” (240mm)× 4.7” (120mm)
Net Weight 11 lbs (5 kg) 14.4 lbs (6.5 kg)
Environmental Specifications Freedom Xi 1000 Freedom Xi 2000
Ambient Temperature:
-4 –122 ºF (-20 –50 ºC), with output derated above 77 ºF (25 °C)
-40–158 ºF (-40–70 ºC)
Humidity: Operation/Storage 5–95% RH, non-condensing
System Specifications Freedom Xi 1000 Freedom Xi 2000
Transfer relay rating 30A, 2.0hp (24A required derating by electrical code in North America)
Transfer time (shore to inverter)
Transfer time (inverter to shore)
<40 milliseconds
<40 milliseconds with a 20-second delay
Transfer voltage (shore to inverter)
Transfer voltage (inverter to shore)
<95 V and >135 V
<130 V and >100 V
Cooling Fan, activated by any of the following:
•High internal temperature
•High AC output power
Operating Temperature Range
S
torage Temperature Range
Freedom XI Owners Guide.book Page 31 Friday, September 18, 2015 2:57 PM