34 Truecharge2 Series Battery Charger Owner’s Guide
Configuring the Truecharge2 Battery Charger
Once the charger is connected to at least one battery bank and to AC, it is
live and it may be configured. The indicator LEDs on the onboard display
will illuminate for a second (power on test) before reporting charging and
battery status information.
Configuring the Charger Mode
NOTE: By default, the Charger Mode is set to 3-Stage.
1. Press and hold the Charger Mode Select button for three seconds to
advance to the next setting.
2. Select the proper charger mode.
The LEDs will indicate which of the two modes is being selected:
three-stage (default) or two-stage.
Configuring the Battery Bank Type
NOTE: By default, the battery type is set to Flooded.
1. Press and hold the Battery Type Select button for three seconds to
advance to the next setting.
2. Select the proper battery type.
The LEDs will indicate which of the five types is being selected:
Flooded (default), GEL, Lead Calc., AGM, and Custom. The Custom
setting is indicated when all four battery type LEDs are illuminated.
This setting should only be used if a custom algorithm has been
programmed by Xantrex or a designated OEM.
Figure 11
Onboard Display Panel
TC2 204060 Series BattChg Owners Guide.book Page 34 Friday, July 8, 2011 11:44 AM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xantrex truecharge 2 series and is the answer not in the manual?

Xantrex truecharge 2 series Specifications

General IconGeneral
Input Voltage90-265 VAC
Input Frequency47-63 Hz
Number of Banks3
DimensionsVaries by model
WeightVaries by model
Output Voltage12 VDC or 24 VDC
Output Current20A, 40A, or 60A
Battery TypesFlooded, Gel, AGM
Charging Stages3-stage (Bulk, Absorption, Float)
Protection FeaturesOvervoltage, Overcurrent, Short Circuit, Reverse Polarity, Over Temperature
Operating Temperature-20°C to +50°C