EasyManuals Logo

Xantrex truecharge 2 series User Manual

Xantrex truecharge 2 series
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #58 background imageLoading...
Page #58 background image
46 Truecharge2 Series Battery Charger Owner’s Guide
Using A Generator As Source Power
The Truecharge2 Battery Charger can be run from a regular AC power
source or from an alternate power source such as a generator. Refer to “AC
Input Specifications” on page 54 for AC input current draw to determine
the size of generator you need. Many generators provide output voltage that
is modified sine wave or modified square wave (MSW) rather than the true
sine wave (TSW) that your utility provides.
If a generator needs to run on full load capacity to supply charging current
to the battery via the battery charger, its output frequency and amplitude
may become unstable. This scenario can cause the battery charger to
shutdown. Using the current limiting feature
1
from the remote panel can
help avoid this scenario.
The Truecharge2 Battery Charger may be used with MSW generators but
its lifetime may be reduced somewhat depending on the severity of any
peak voltage overshoots, and the severity of waveshape rise times.
1.See “Configuring the Maximum Output Current Percentage of the Charger” on the
Truecharge2 Remote Panel Owner’s Guide.
TC2 204060 Series BattChg Owners Guide.book Page 46 Friday, July 8, 2011 11:44 AM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xantrex truecharge 2 series and is the answer not in the manual?

Xantrex truecharge 2 series Specifications

General IconGeneral
Input Voltage90-265 VAC
Input Frequency47-63 Hz
Number of Banks3
DimensionsVaries by model
WeightVaries by model
Output Voltage12 VDC or 24 VDC
Output Current20A, 40A, or 60A
Battery TypesFlooded, Gel, AGM
Charging Stages3-stage (Bulk, Absorption, Float)
Protection FeaturesOvervoltage, Overcurrent, Short Circuit, Reverse Polarity, Over Temperature
Operating Temperature-20°C to +50°C