Appendix special soft device list
ID
Function
Description
M8050
I000□
Forbid the input interruption 0
After executing EI instruction, even the
interruption is allowed, but if M acts at this
time, the correspond input interruption
couldn’t act separately
E.g.when M8050 is ON, interrupt I000 is
forbidden
M8051
I010□
Forbid the input interruption 1
M8052
I020□
Forbid the input interruption 2
M8053
I030
Forbid the input interruption 3
M8054
I040
Forbid the input interruption 4
M8055
I050
Forbid the input interruption 5
M8056
I40□□
Forbid the time interruption 0
After executing EI instruction, even the
interruption is allowed, but if M acts at this
time, the correspond time interruption
couldn’t act separately
M8057
I41□□
Forbid the time interruption 1
M8058
I42□□
Forbid the time interruption 2
M8059
Forbid the interruption
Forbid all interruption
ID
Function
Description
M8067
Operation error
happen when calculating
M8070
Scan time out
M8071
No user program
Internal codes parity error
M8072
User program error
execution codes or configure table parity error
Interruption (M8050-M8059)
M
Error Testing (M8067-M8072)