X can use as normal input terminals when there are no high speed pulses input. In the
following table, 2 means double frequency; 4 means quadruple frequency; 2/4 means that
double frequency and quadruple frequency can be adjusted.
XD2-16
Increasing mode
AB phase mode
HSC0
HSC2
HSC4
HSC6
HSC8
HSC10
HSC12
HSC0
HSC2
HSC4
HSC6
HSC8
Max
frequency
10K
10K
10K
5K
5K
5K
Quadruple
frequency
2/4
2/4
2/4
Counter
interruption
X000
U
A
X001
B
X002
Z
X003
U
A
X004
B
X005
Z
X006
U
A
X007
B
X010
Z
XD3-16, XL3-16
Increasing mode
AB phase mode
HSC0
HSC2
HSC4
HSC6
HSC8
HSC10
HSC12
HSC0
HSC2
HSC4
HSC6
HSC8
Max
frequency
80K
10K
10K
50K
5K
5K
Quadruple
frequency
2/4
2/4
2/4
Counter
interruption
X000
U
A
X001
B
X002
Z
X003
U
A
X004
B
X005
Z
X006
U
A
X007
B
X010
Z
XD2-24/32/42/48/60, XD3-24/32/48/60, XD5-16/24/32/42/48/60, XD5E-24/30/48/60,
XL3-32, XL5-16/32, XL5E-16/32
Increasing mode
AB phase mode
HSC0
HSC2
HSC4
HSC6
HSC8
HSC10
HSC12
HSC0
HSC2
HSC4
HSC6
HSC8
Max
frequency
80K
80K
10K
50K
50K
5K
Quadruple
frequency
2/4
2/4
2/4
Counter
interruption
X000
U
A
X001
B
X002
Z
X003
U
A
X004
B
X005
Z
X006
U
A