263
Normally ON/OFF, rising
edge
2)Operands
Specify remote communication station no.
Specify remote coil start address number
Specify start address number of local receipt
coils
Specify serial port number
3)Suitable soft components
Notes: D includes D, HD; TD includes TD, HTD; CD includes CD, HCD, HSCD, HSD;
DM includes DM, DHM; DS includes DS, DHS. M includes M, HM, SM; S includes S
and HS; T includes T and HT; C includes C and HC.
INPR K1 K500 K3 M1
X0
K2
S1· S2· S3· D1· D2·
Read input coil, Modbus function code is 02H.
Serial port: K0~K5. K0: Port0 (RS232), K1: Port1(RS232), K2: Port2(RS485), K3:
Port3(left extension port), K4: Port4(above extension port 1), K5: Port5(above
extension port 2).
Operand S3: K1~K2000, max input coil number is 2008.
When X0 is ON, INPR instruction is executed, Modbus read write flag SM160(serial
port2) is set ON, SM160 is set OFF when the execution is completed. If a
communication error occurs and the number of resend is set, it will be automatically
resend. Users can check the relevant registers to determine the cause of the error. The
execution result of Modbus read and write instructions of serial port 2 is in SD160.