Installation, Operation, and
Maintenance Manual
886211_9.0
6020.180/090
Concertor

Table of Contents

Questions and Answers

  • H
    hernandezthomasAug 12, 2025
    How to resolve communication failure with Dirigo[™] Service Tool for Xylem Water Pump?
    • W
      wheelerelizabethAug 12, 2025
      If the Dirigo™ Service Tool fails to communicate with the Xylem Water Pump unit, the control leads might not be correctly connected. Ensure the leads are correctly connected and try running the Dirigo™ Service Tool again. Also, the value for Com port under Control > Pump communication might be incorrect. Select the correct value and try running the tool again.
  • Y
    yatesmatthewAug 15, 2025
    How to troubleshoot a Xylem 6020.180/090 that does not start?
    • D
      Darren VillarrealAug 16, 2025
      If your Xylem Water Pump isn't starting, the issue might be with the power supply. Make sure the main power switch is on, the fuses are intact, and there's voltage in all phases of the supply line. Also, check that all fuses have power, are securely fastened, and the motor cable isn't damaged. If the sum alarm is active, contact a sales or authorized service representative or use the Dirigo™ Service Tool application to read the alarm codes.
  • J
    jamespriceAug 23, 2025
    Why does my Xylem Water Pump keep stopping?
    • A
      allenmichaelAug 23, 2025
      If your Xylem Water Pump stops unexpectedly, it could be due to a power supply issue. Check the power supply to the pump. Alternatively, there might be a disconnection between the pump and the controller / RTU / PLC. In this case, check the power supply to the controller, restart the controller, and inspect T3 and T4.
  • B
    baileyjessicaAug 31, 2025
    How to fix a Xylem 6020.180/090 Water Pump that doesn't receive commands from the controller?
    • I
      Ian SmithAug 31, 2025
      If your Xylem Water Pump isn't receiving commands from the controller, it might be a communication issue. First, check the power supply to the controller. Then, ensure that the PUMP COMMS indicator is lit on the gateway. Try restarting the controller. Also, check T3 and T4.
  • E
    Eric MaysSep 3, 2025
    What to do if Xylem 6020.180/090 Water Pump starts but stops after 10 seconds?
    • J
      Jamie HayesSep 3, 2025
      If your Xylem Water Pump starts but stops after 10 seconds, the FLS might be triggering the sum alarm due to leakage into the drive unit. To check this, turn the power off and on to restart the pump. If it runs for 10 seconds and stops again, disconnect the pump and empty the liquid from the drive unit. If the pump acts differently, contact a sales or authorized service representative or use the Dirigo™ Service Tool application to read the alarm codes.
  • J
    Joseph RoseSep 7, 2025
    Why is the impeller not rotating in my Xylem Water Pump?
    • C
      Christopher PhamSep 7, 2025
      If the impeller in your Xylem Water Pump isn't rotating, it might be stuck. Check that the impeller can be rotated, and clean both the impeller and the sump.
  • J
    John MartinezNov 18, 2025
    What to do if Xylem Water Pump delivers too little or no water?
    • M
      mackenziemartinezNov 18, 2025
      If your Xylem Water Pump is delivering too little or no water, several issues could be the cause. Start by checking that all valves are in the correct positions, and replace them if necessary. Ensure correct installation according to media flow and proper opening. Inspect the impeller for rotation difficulty, clean it and the sump, and verify correct trimming. Clear any obstructions in the pipes and seal any leaks in pipes and joints. Replace worn parts if there's wear on the impeller, pump, and casing. Ensure the liquid level isn't too low by checking the level sensor and providing priming equipment if needed. Check if the Set Power or Set Speed parameter is too low and change the settings. If the impeller rotates in the incorrect direction, contact a sales or authorized service represent...
  • J
    Joshua MccormickNov 26, 2025
    What causes a Xylem 6020.180/090 to start, stop, and start again quickly?
    • J
      julie22Nov 26, 2025
      If your Xylem Water Pump starts, stops, and then restarts rapidly, it could be due to back-flow filling the sump to the start level again. Check that the distance between the start and stop levels is sufficient, the non-return valves are working correctly, and the length of the discharge pipe between the pump and the first non-return valve is sufficiently short. Another cause may be the self-holding function of the contactor malfunctioning. Check the contactor connections, the voltage in the control circuit, the functioning of the stop-level regulator, and the voltage drop in the line at the starting surge. If the power supply is incorrect and the sum alarm is active after ten cycles, contact a sales or authorized service representative or use the Dirigo™ Service Tool application to read t...

Summary

Introduction and Safety

User Safety & Special Hazards

Guidelines for safe operation, user safety, and identification of special hazards.

Ex-Approved Product Handling

Special handling instructions for products in explosive atmospheres.

Installation Procedures

Mechanical Installation Precautions

General, electrical, site, and fastener safety precautions for installation.

Electrical Installation Precautions & Requirements

Safety precautions and requirements for electrical connections.

Operation & Maintenance

Operation Precautions & Pump Startup

Safety measures and steps for operating and starting the pump.

Troubleshooting Guide

Xylem 6020.180/090 Specifications