6.5.4.3 Install the Adaptive N
impeller: P, S, T, Z installations
To see which pumps are Adaptive N
, see Product Description on page 11.
1. Before mounting the impeller, check that the sleeve moves freely up and down by
pushing on it.
When the sleeve is released, it should be fully pushed out again. If the sleeve does not
move freely, or does not come fully out, then replace the impeller unit.
WS008396C
2. Check that the adjusting screw is correctly positioned in the new impeller.
WS010021C
3. Prepare the shaft:
a) Polish off any flaws with a fine emery cloth.
The end of the shaft must be clean and free from burrs.
b) Coat the inner conic and the outer cylindrical surfaces of the sleeve with a thin layer
of grease.
WS008329B
The proper lubrication is grease for bearings, for example Exxon Mobil Unirex N3,
Mobil Mobilith SHC 220 or equivalent.
NOTICE:
Surplus grease can cause the impeller to become loose. Remove surplus grease
from conical and/or cylindrical surfaces of shafts and/or sleeves.
4. Mount the impeller sleeve and impeller.
6 Maintenance
Flygt 3102 Installation, Operation, and Maintenance Manual 63

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xylem Flygt 3102 Series and is the answer not in the manual?

Xylem Flygt 3102 Series Specifications

General IconGeneral
BrandXylem
ModelFlygt 3102 Series
CategoryWater Pump
LanguageEnglish

Related product manuals