EasyManua.ls Logo

Yale Assure Lock YRD226 - Configurable Parameters; Parameter Settings and Descriptions

Yale Assure Lock YRD226
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
Configurable Parameters
Table 3 - Configurable Parameters
Param.
Num.
Name
Length
Configuration Properties
Info
Info
String
Format
Min
Max
Default
1
Volume
Signed
Integer
1 byte
0x01
(High
Volume)
0x03
(Silent)
0x02 (Low
Volume)
Set Volume Level to
high (1), low (2), or
silent (3).
53
2
Auto Relock
Unsigned
Integer
1 byte
0x00
(Disable)
0xFF
(Enable)
0x00
(Disable)
Set Auto Relock
feature to enable or
disable.
45
3
Relock time
Signed
Integer
1 byte
0x0A (10
seconds)
0xB4 (180
seconds)
0x1E (30
seconds)
Adjust the time your
lock will auto relock.
43
4
Wrong
Code Entry
Limit
Signed
Integer
1 byte
0x03
0x0A
0x05
Adjust the limit for
wrong code entries
allowed by your
lock.
61
5
Language
Signed
Integer
1 byte
0x01
(English)
0x03
(French)
0x01
(English)
Set the language to
English (1), Spanish
(2), or French (3).
60
7
Shut down
time
Signed
Integer
1 byte
0x0A (10
seconds)
0x84 (132
seconds)
0x3C (60
seconds)
Adjust the time your
lock is shutdown
after reaching its
80