4 Installation
20 09.2019
ba-o.4.1.3-en-2.2-y
4 Installation
4.1 Dimensions
100 × 110 × 75 mm (W × H × D)
4.2 Attachment possibilities
Snap-on attachment on 35 mm top hat rail (EN 50022-35)
Screw attachment enclosure bottom (M4) using pull-out sliders
4.3 Cable connection
See section “Technical data”.
4.4 Cables
Install sensor cables (load sensor, temperature sensor) and power lines separately of
each other. (Example: Installation in different ducts or spatially separate bundles)
The lengths of the cables for sensors and digital control signals may not exceed the
maximum values specified in the chapter "Technical data".
4.5 Mounting
Mounting in a switch cabinet, at least IP 54.