8 Technical data
09.2019 31
AC voltage:
24 V 50 / 60 Hz
42 V 50 / 60 Hz
48 V 50 / 60 Hz
110/120 V 50 / 60 Hz
230 V 50 / 60 Hz
DC voltage:
24 V DC
Residual ripple:
±5 %
Power consumption at rated voltage
Fuse protection control current circuit
Signal level input inactive
Signal level input active
Control relays per EN 13849-1, Cat. 2
Utilization category
- EN 60947-5-1,
AC15: 250 V / 2 A (inductive load cos φ=0.7), 5 A (resistive load)
DC13: 30 V / 2 A
At +70 °C (optional)
AC15: 250 V / 1.5 A (inductive load cos φ=0.7), 3 A (resistive load)
Signaling relays / Temperature monitoring relay
Utilization category
- EN 60947-5-1,
AC15: 250 V / 2 A (inductive load cos φ=0.7), 5 A (resistive load)
DC13: 30 V / 2 A
At +70 °C (optional)
AC15: 250 V / 1.5 A (inductive load cos φ=0.7), 3 A (resistive load)
Passive DMS sensor, full bridge
Max. error of measurement at 25 °C referred to the
smallest-possible cut-off point
Maximum total initial resistance
Max. 1500 (IEC / EN 60947-8)
Maximum release resistance:
Clearances and creepage distances per IEC / EN 60664
Rated insulation voltage 250 V AC
Pollution degree 2
Protection class II
Overvoltage categories III