8 Technical data
32 09.2019
EN 60068-2-27 10 g – 11 ms
EN 60068-2-6 3 mm at 2...9 Hz; 0.5 g at 9...200 Hz
EN 61000-6-2-7 Immunity for devices intended to perform functions in safety-
related systems (functional safety) at industrial sites
EN 61000-6-3 Emission standard for residential, commercial and light-industrial
environments
Temperature range operation
-20 °C ... +55 °C (standard)
-20 °C ... +70 °C (optional)
100 × 110 × 75 mm (W × H × D)
30 box terminals with captive plus-minus screws
Per box terminal: 1 × 4 mm
2
solid or 1 × 2.5 mm
2
stranded wire with wire ferrules
or 2 × 1.5 mm
2
stranded wire, with wire ferrules
Tightening torque of the screw terminals 0.5 Nm
Maximum cable length
- Digital control signals
- Temperature inputs
- Sensor inputs (shielded)
Safety parameter values per ISO 13849-1
Requirements for sensors:
Requirements for the contactor:
> 1,300,000 (assumed cycles/year: 150,000)