35
DBR10/DBR12/DBR15
The result is displayed in output window as shown below.
When Normal
D-CONTOUR
switch
PASS: SW D-CNTR-FOH xxxx[mV] (xxxx)
PASS: SW D-CNTR-OFF xxxx[mV] (xxxx)
PASS: SW D-CNTR-MONI xxxx[mV] (xxxx)
HPF switch
PASS: SW HPF-120HZ xxxx[mV] (xxxx)
PASS: SW HPF-100HZ xxxx[mV] (xxxx)
PASS: SW HPF-OFF xxxx[mV] (xxxx)
検査結果はアウトプットウインドウへ下記のように
表示されます。
正常時
D-CONTOUR
スイッチ
PASS: SW D-CNTR-FOH xxxx[mV] (xxxx)
PASS: SW D-CNTR-OFF xxxx[mV] (xxxx)
PASS: SW D-CNTR-MONI xxxx[mV] (xxxx)
HPF スイッチ
PASS: SW HPF-120HZ xxxx[mV] (xxxx)
PASS: SW HPF-100HZ xxxx[mV] (xxxx)
PASS: SW HPF-OFF xxxx[mV] (xxxx)
When out of order
D-CONTOUR
switch
FAIL: SW D-CNTR-FOH *[voltage] *[value]
FAIL: SW D-CNTR-OFF *[voltage] *[value]
FAIL: SW D-CNTR-MONI *[voltage] *[value]
HPF switch
FAIL: SW HPF-120HZ *[voltage] *[value]
FAIL: SW HPF-100HZ *[voltage] *[value]
FAIL: SW HPF-OFF *[voltage] *[value]
*[voltage]= A voltage value set as 3 steps by the slide
switch [mV]
*[value]= 12bit A/D value
Troubleshooting
If you fail, check wire connection and the following parts.
CPU(PCBDSP:IC504-60pin)→
D-CONTOUR
switch
CPU(PCBDSP:IC504-59pin)→ HPFswitch
故障時
D-CONTOUR
スイッチ
FAIL: SW D-CNTR-FOH *[voltage] *[value]
FAIL: SW D-CNTR-OFF *[voltage] *[value]
FAIL: SW D-CNTR-MONI *[voltage] *[value]
HPF スイッチ
FAIL: SW HPF-120HZ *[voltage] *[value]
FAIL: SW HPF-100HZ *[voltage] *[value]
FAIL: SW HPF-OFF *[voltage] *[value]
*[voltage]=スライドスイッチで、3段階に設定され
た電圧値[mV]
*[value]=12bitAD値
トラブルシューティング
失敗した場合、次の部品及び結線を確認します。
CPU(PCBDSP:IC504-60pin)→
D-CONTOUR
スイッチ
CPU(PCBDSP:IC504-59pin)→ HPF スイッチ
If status received from fi rmware is not the one intended,
whether or not to performagain the test that status of
switch is the same is confirmed. The test is performed
again with “Retry” button, and not performed again with
“Cancel” button.
ファームウェアから受信した状態が意図した状態で
ない場合は、同一スイッチ状態のテストを再度実行
するか確認します。「Retry」ボタンで再テストを行
い、「Cancel」ボタンで再テストを行いません。