8-53
ELECTRICAL COMPONENTS
Radiator fan motor relay
Result
Continuity
(between “3” and “4”)
ET5YU1021
CHECKING THE TURN SIGNAL/HAZARD
RELAY
1. Check:
• Turn signal/hazard relay input voltage
Out of specification → The wiring circuit from
the main switch to the turn signal/hazard re-
lay coupler is faulty and must be repaired.
a. Connect the pocket tester (DC 20 V) to the
turn signal/hazard relay terminal as shown.
Turn signal/hazard relay input
voltage
DC 12 V
▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼
Pocket tester
90890-03112
• Positive tester probe → brown “1”
• Negative tester probe → ground
▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼
2. Check:
• Turn signal/hazard relay output voltage
Out of specification → Replace.
Turn signal/hazard relay output
voltage
DC 12 V
▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼
a. Connect the pocket tester (DC 20 V) to the
turn signal/hazard relay terminal as shown.
Pocket tester
90890-03112
• Positive tester probe → brown/white “1”
• Negative tester probe → ground
▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼
EAS28050
CHECKING THE RELAY UNIT (DIODE)
1. Check:
• Relay unit (diode)
Out of specification → Replace.
Pocket tester
90890-03112
NOTE:
The pocket tester and the analog pocket tester
readings are shown in the following table.
b. Turn the main switch to “ON”.
c. Measure the turn signal/hazard relay output-
voltage.
1. Positive battery terminal
2. Negative battery terminal
3. Positive tester probe
4. Negative tester probe
b. Turn the main switch to “ON”.
c. Measure the turn signal/hazard relay input
voltage.