Sepalizing in indicator,Being perfect in indicator
Shanghai Yaohua Weighing System Co.,Ltd.
14
maximum unit price is :9999.99 and maximum sum is:9999.99.If the
sum is over 9999.99,it will display “oUer”.
6. Counting operation
Two methods of the counting operation:one is the unit weight is
unknown,then get the unit weight by putting some quantities of the
samples and putting the number;the other is the unit weight is
known,then press[Unit W] to operate counting.Pls see the following
for detail:
6.1. Unit weight unkown:Put some quantities of samples,then while
the weight is stable,input the actual number of the
samples,press[Quantity] for confirm.After the indicator
calculate the unit weight,then counting operation can be
performed.
6.2. Unit weight known:Input the unit weight of the to be counted
sample,press[Unit W] for confirm,then counting operation can
be performed.
Notes:
A The unit of the unit weight is g.And the decimal point of the
unit weight is decided by that of the weight.
B For 6.1,the advised sample number is over 50.
C If the weight is negative,the indicator won’t count.If the unit
weight is less than 0.25 division,the indicator will
display”L” to show the unit weight isn’t enough.If the unit
weight calculated by “Quantity” is less than 0.05 division,the
indicator will display”Err 10” to show sample not enough.
7. Accumulation(M+) and Accumulation clear(MC)
The operation is shown as below: